Inspection
Inspection Details
Equipment ID
14546
14546
Inspection Date
5/8/2019
5/8/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Clyde Johnson
Clyde Johnson
Mechanic Name
Michael Gallaher
Michael Gallaher
Relief Valve Pressure
Slide
Na
Na
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
92c7b94a-01d8-450f-9f4d-5e3128cfafb5
92c7b94a-01d8-450f-9f4d-5e3128cfafb5
Location
National Rent to Own
3458 UNION BLVD, SAINT LOUIS, MO
3458 UNION BLVD, SAINT LOUIS, MO
Owner
National Rent to Own
3407 BRIDGELAND DR, BRIDGETON, MO 63044-2604
3407 BRIDGELAND DR, BRIDGETON, MO 63044-2604
Billing
Attn: National Rent to Own
3407 BRIDGELAND DR, BRIDGETON, MO 63044-2604
3407 BRIDGELAND DR, BRIDGETON, MO 63044-2604
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (K) - Car Platforms and Car Slings | (K)2 | Elevators shall have warning chains hung within 2" of the edge of the platform on the entrance sides. Chains shall be of number ten (10) US gauge wire or of equal size. Chains shall extend not less than 5' below the platform and shall not be spaced more than 4" apart. | 11/6/2020 | ||
| MO Minimum : Elevators | (I) - Pits | (I)2 | Replace pit channel. | 11/6/2020 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Provide code compliant car lighting (2.5 ft candles) | 11/6/2020 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Car top light needs to be wired per NEC. | 11/6/2020 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Provide guard on lights in machine room. | 11/6/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Provide updated fire extinguisher in machine room. | 11/6/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | Seal missing on governor. | 11/6/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | Provide maintenance on brake system. Clean and lub pins. | 11/6/2020 | ||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)1(A) | Provide anti-rotation hoist ropes. | 11/6/2020 | ||
| MO Minimum : Elevators | (I) - Pits | (I)5 | Provide pit ladder. | 11/6/2020 | ||
| MO Minimum : Elevators | (I) - Pits | (I)2 | Provide counterweight buffer. | 11/6/2020 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)1 | Cab is missing section of car top enclosure, replace as needed. | 11/6/2020 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current operating certificate. | 11/6/2020 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Provide guards on lights in machine room. | |||
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | Lights in car shall be code compliant, 2.5 ft candles, minimum. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Provide updated fire extinguisher in machine room. |