Inspection
Inspection Details
Equipment ID
19313
19313
Inspection Date
5/8/2019
5/8/2019
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Derek Rankin
Derek Rankin
Mechanic Name
David Tiemann
David Tiemann
Relief Valve Pressure
Slide
14
14
Governor Rope Pull
330/700
330/700
Door Closing Force
16
16
External ID
37da9734-89cf-4f86-a85c-83d2485f8385
37da9734-89cf-4f86-a85c-83d2485f8385
Location
100 North Tucker Bldg
100 N TUCKER BLVD, SAINT LOUIS, MO
100 N TUCKER BLVD, SAINT LOUIS, MO
Owner
St. Louis University
3500 LINDELL BLVD, SAINT LOUIS, MO 63103-1021
3500 LINDELL BLVD, SAINT LOUIS, MO 63103-1021
Billing
Attn: St. Louis University
3500 LINDELL BLVD, SAINT LOUIS, MO 63103-1021
3500 LINDELL BLVD, SAINT LOUIS, MO 63103-1021
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | conversion - reinspect | x | Door Edge is not overridden on Phase 1 and 11 | 5/8/2019 | |
MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | x | Suspension ropes need to be shortened. | 6/16/2020 | |
MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)2 | Anti spin-out cable is broken. Needs to be replaced. | 2/2/2021 | ||
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | Door does not stay open during Phase II. | 6/16/2020 | |
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | Wrong key switch is in car for fire service. | 6/16/2020 | |
MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | x | In car pull stop switch needs to be tied into the alarm bell. | 6/16/2020 | |
MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | x | x | Suspension ropes need to be shortened. Car does not make up final limit on car top inspection. RED TAGGED. | 9/23/2020 |
MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)1(A) | Anti spin out cable is broken. | 2/2/2021 | ||
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | x | Door does not stay open during Phase I operation. RED TAGGED. | 9/23/2020 |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency alarm and bell do not work. | 9/23/2020 | |
MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | x | In car pull top switch needs to be accompanied by an alarm when activated. | 9/23/2020 | |
A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.7.9.1 | x | Machine room illumination shall be 19fc minimum | 11/5/2024 | |
MO Minimum : Elevators | (S) - Fire Service | 211.8 Switch Keys | x | All fire recall switches in a building shall be keyed alike | 11/5/2024 | |
A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.8.2 | x | Supply permanent power to rescue phone. Extension cords do not meet the NFPA 70 codes | 11/5/2024 | |
A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 2.14.7 | x | Standard receptical in the elevator cab shall be removed or replaced with a GFIC receptacle | 11/5/2024 | |
A17.1-2016 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4.5 | x | Repair and retest the Shunt trip circuit | 11/5/2024 | |
A17.1-2016 : Elevators | 2.12 - Controller Wiring, Fuses, Grounding, Etc. | 2.26.1 | Shunt trip currently not functioning when car is on Fire recall bypass | |||
A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.8 Switch Keys | All elevators in a single building shall have Firerecall switches keyed alike | |||
A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.8 Switch Keys | x | All Fire recall key switches shall be keyed alike within 30 days. (12/20/24) |