Inspection
Inspection Details
Equipment ID
20406
20406
Inspection Date
5/7/2019
5/7/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
David Tiemann
David Tiemann
Relief Valve Pressure
330
330
Slide
Governor Rope Pull
Door Closing Force
21
21
External ID
c3b6c3dc-8b49-4ebb-95f4-a819361f128e
c3b6c3dc-8b49-4ebb-95f4-a819361f128e
Location
Hotel Ignacio
3407 OLIVE ST, SAINT LOUIS, MO
3407 OLIVE ST, SAINT LOUIS, MO
Owner
Hotel Ignacio
3407 OLIVE ST, SAINT LOUIS, MO 63103-1116
3407 OLIVE ST, SAINT LOUIS, MO 63103-1116
Billing
Attn: HOTEL IGNACIO
3407 OLIVE ST, SAINT LOUIS, MO 63103-1116
3407 OLIVE ST, SAINT LOUIS, MO 63103-1116
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Water and excessive corrosion in the pit shall be addressed. | 2/2/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | No | No | There is excessive corrosion on the pit equipment. Remove corrosion and take corrective measures to eliminate corrosion. | 2/2/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.11.2.1.2(e) (Re-Inspection) | No | No | Can not use machine room as storage. | 2/2/2021 |
| A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | Yes | No | OSV needs to be tested with full load within 90 days. | 8/23/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | No | No | Pit light does not work. Replace or repair item as needed. | 9/4/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.5 Sump pump shall be provided | Yes | No | Pit had water in it because sump pump does not work causing major corrosion in the pit and on the pit channel. Needs to be addressed. | 8/23/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Clean the pit. | 9/4/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Provide means to prevent ground water from entering the pit. | 9/4/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Provide means to prevent rust on the existing pit equipment. | 9/4/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Provide current year tested fire extinguisher in the elevator machine room. | 9/4/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.7.2.1 | No | No | Remove all non elevator related items from the elevator machine room. | 9/4/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 9/4/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The elevator ADA telephone inside the elevator is not working properly. Check & repair the programming of this phone for proper operation and passenger safety. Re-inspection required |