Inspection
Inspection Details
Equipment ID
1986
1986
Inspection Date
6/13/2019
6/13/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Jeremiah Dugger
Jeremiah Dugger
Relief Valve Pressure
Slide
n/a
n/a
Governor Rope Pull
n//a
n//a
Door Closing Force
25
25
External ID
597436ed-aeeb-46e8-8ef3-c3c9bf7ac331
597436ed-aeeb-46e8-8ef3-c3c9bf7ac331
Location
Hulston Cancer Center
3800 S NATIONAL AVE, SPRINGFIELD, MO
3800 S NATIONAL AVE, SPRINGFIELD, MO
Owner
Attn: Lester E Cox Medical Center
Lester E Cox Medical Center
1423 N JEFFERSON AVE, SPRINGFIELD, MO 65802
Phone: (417) 269-4090
Email: vickie.easterly@coxhealth.com
Lester E Cox Medical Center
1423 N JEFFERSON AVE, SPRINGFIELD, MO 65802
Phone: (417) 269-4090
Email: vickie.easterly@coxhealth.com
Billing
Attn: Accounts Payable
Lester E Cox Medical Center
PO BOX 9550, SPRINGFIELD, MO 65801
Phone: (417) 269-4090
Email: vickie.easterly@coxhealth.com
Lester E Cox Medical Center
PO BOX 9550, SPRINGFIELD, MO 65801
Phone: (417) 269-4090
Email: vickie.easterly@coxhealth.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)12 (Door open zones) | Yes | No | 1.18 door restrictor needs repair | 2/28/2019 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | 2.4.2.1 Suspension ropes need to be shortened | 2/28/2019 |
| MO Minimum : Elevators | (E) - Machines | (E)1 | No | No | 2.17 seals need to be replaced on driver | 1/7/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | 8.6.3.1 replace shackle bushings car side | 8/23/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | 8.6.1.2.1(2) or 8.6 clean car top.4.9 | 8/23/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | 8.6.4.15 emergency light needs battery | 8/7/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | 8.6.3.1 replace shackle bushings car side | 8/23/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | No | No | Door pressure exceeds 30lbs | 8/31/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | telephone could call out but they could not give location | 6/23/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | counterweight roller guide needs replaced | 8/31/2020 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)7 | Yes | Yes | A17.1-2016--(8.6.4.12.1) all moving parts work correctly--governor jaws will not grip rope and set the safeties | 6/23/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | telephone would call out but they could not give location | 5/17/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | No | No | door pressure exceeds 30lbs | 8/31/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated certificate | 3/1/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light/bell failed | 4/2/2024 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Ropes undersized 8.6.3.2 | 4/2/2024 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Must make emergency alarm operable. 8.6.4.15 | 10/15/2024 |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Car Emergency System (Re-Inspection) | Yes | No | Must make emergency light operable. 8.6.4.15 | 10/15/2024 |