Inspection
Inspection Details
Equipment ID
2888
2888
Inspection Date
6/6/2019
6/6/2019
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Derek Rankin
Derek Rankin
Mechanic Name
Michael Gallaher
Michael Gallaher
Relief Valve Pressure
Na
Na
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
Na
Na
External ID
1db9c381-9fda-4836-b097-32b5bf29c768
1db9c381-9fda-4836-b097-32b5bf29c768
Location
Arsenal Pump Station
3000 S WHARF ST, ST. LOUIS, MO
3000 S WHARF ST, ST. LOUIS, MO
Owner
Metropolitan Sewer District STL
2350 MARKET ST, SAINT LOUIS, MO 63103-2519
2350 MARKET ST, SAINT LOUIS, MO 63103-2519
Billing
Attn: Metropolitan Sewer District
2350 MARKET ST, SAINT LOUIS, MO 63103-2519
2350 MARKET ST, SAINT LOUIS, MO 63103-2519
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Post current state certificate in themachine room | 6/2/2020 |
| conversion | conversion | n/a | No | No | Prove handel on top floor hoistway door | 6/2/2020 |
| conversion | conversion | conversion - reinspect | Yes | No | Repair phone in car | 6/6/2019 |
| conversion | conversion | n/a | No | No | Provide missing access panel to machine space | 6/2/2020 |
| conversion | conversion | n/a | No | No | Install guard on light in car | 6/2/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 4/23/2020 |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)6 | No | Yes | Hoistway doors shall comply with A17.1 1978 Part XV | |
| MO Minimum : Elevators | (R) - Power Operated Special Purpose Elevators | (R)9 | No | No | A car door shall be provided at each entrance, at least 7' high. The door or gate shall be provided with interlocks. | 6/2/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Maintenance records and electrical prints shall be provided. | 6/2/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Maintenance shall comply with A17.1 2004 | 6/2/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Car safety pan needs to be non-combustible material. | 6/2/2020 |