Inspection
Inspection Details
Equipment ID
22852
22852
Inspection Date
6/7/2019
6/7/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
David Scott
David Scott
Relief Valve Pressure
570
570
Slide
Governor Rope Pull
Door Closing Force
30
30
External ID
b423e6ab-1fe0-4033-9848-89db1fecfe02
b423e6ab-1fe0-4033-9848-89db1fecfe02
Location
Salvation Army
2900 WASHINGTON AVE, SAINT LOUIS, MO
2900 WASHINGTON AVE, SAINT LOUIS, MO
Owner
Salvation Army- St. Louis
2900 WASHINGTON AVE, SAINT LOUIS, MO 63103-1306
2900 WASHINGTON AVE, SAINT LOUIS, MO 63103-1306
Billing
Attn: Salvation Army- St. Louis
2900 WASHINGTON AVE, SAINT LOUIS, MO 63103-1306
2900 WASHINGTON AVE, SAINT LOUIS, MO 63103-1306
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | 1) The movement of the car initiated and maintained by the access switch at the lowest landing shall be limited in the up direction to the point where the bottom of the platform guard is even with hoistway entrance header. The platform guard when car is ran up is in the hoistway entrance. | 6/28/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.35 - Supply Line and Shutoff Valve | 3.19 | No | No | Shut off valve with pressure gauge fitting, and manual lowering valve shall be provided and identified. | 6/28/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.37 - Pressure Switch | 3.26.8 Pressure Switch | No | No | Pressure switch shall be provided in the line between cylinder and valve. Unit not red-tagged. | 6/28/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 9/1/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Fire extinguisher needs to be serviced. | 8/28/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 2.14.7.1.3 Provide Auxiliary Lighting | Yes | No | emergency light shall work on battery power | 10/26/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm shall work on battery power | 10/26/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency communication inoperable. Re-inspection required | 10/26/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | Emergency light & alarm is not working on battery power. Re-inspection required | 10/26/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The emergency phone fails to establish two-way communication. (Reinspect) | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | The emergency light works on battery until pressing the alarm button, and then it extinguishes (Reinspect) | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide a fire extinguisher at the second landing near the elevator controller. |