Inspection
Inspection Details
Equipment ID
5174
5174
Inspection Date
6/5/2019
6/5/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James Mueller
James Mueller
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
530
530
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
4f206768-9992-4450-bb1b-aff5ec8b514a
4f206768-9992-4450-bb1b-aff5ec8b514a
Location
Schnucks
12332 MANCHESTER RD, DES PERES, MO
12332 MANCHESTER RD, DES PERES, MO
Owner
Attn: Summit Manchester Investors LLC
Summit Manchester Investors LLC
100 S BRENTWOOD BLVD STE 222, SAINT LOUIS, MO 63105
Phone: (314) 994-4274
Email: apowderly@schnucks.com
Summit Manchester Investors LLC
100 S BRENTWOOD BLVD STE 222, SAINT LOUIS, MO 63105
Phone: (314) 994-4274
Email: apowderly@schnucks.com
Billing
Attn: SCHNUCKS
SCHNUCKS
11420 LACKLAND RD, SAINT LOUIS, MO 63146
Phone: (314) 944-4274
Email: apowderly@schnucks.com
SCHNUCKS
11420 LACKLAND RD, SAINT LOUIS, MO 63146
Phone: (314) 944-4274
Email: apowderly@schnucks.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 10/16/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | The pit shall be kept clean from dirt, oil, and debris. | 7/24/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters Emergency Operation: Monthly Testing | No | No | MCP Fire Service testing must be properly documented monthly on log sheet. | 7/24/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door. | 7/24/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 7/24/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Repair or replace noisy/scrapping hoistway door guides. | 7/24/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.36 - Hydraulic Cylinders | 8.6.5.5.1 Examination and Maintenance of Packing Glands and Seals | Yes | No | The packing on the jack is leaking. Correct source of leak and repack jack as needed. | 5/3/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | The pit shall be kept clean from dirt, oil, and debris. | 10/16/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 3.26.10 (Auxiliary Power)(Re-Inspection) | Yes | No | Battery lowering shall work. | 8/27/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 10/16/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.1 | No | No | Access to the machine space shall maintained in a clear and unobstructed manner. | 10/16/2024 |