Inspection
Inspection Details
Equipment ID
13141
13141
Inspection Date
6/18/2019
6/18/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Herbert Neulist
Herbert Neulist
Mechanic Name
Douglas Dalton
Douglas Dalton
Relief Valve Pressure
520
520
Slide
Governor Rope Pull
Door Closing Force
18
18
External ID
1c3d05e0-5e13-4f7e-ab31-57e205ebfc15
1c3d05e0-5e13-4f7e-ab31-57e205ebfc15
Location
Comfort Inn- Pacific
1320 THORNTON ST, PACIFIC, MO
1320 THORNTON ST, PACIFIC, MO
Owner
Comfort Inn-Pacific
1320 THORNTON ST, PACIFIC, MO 63069-1036
1320 THORNTON ST, PACIFIC, MO 63069-1036
Billing
Attn: Comfort Inn-Pacific
1320 THORNTON ST, PACIFIC, MO 63069-1036
1320 THORNTON ST, PACIFIC, MO 63069-1036
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | Perform OSV test. Tag and seal upon completion. | 1/5/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Fire extinguisher in machine room is expired. Replace or have serviced | 1/9/2023 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Emergency phone in car does not work, appears to be an issue with the line. Re-inspection required | 1/9/2023 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be displayed in the machine room | 1/9/2023 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | x | OSV is overdue for testing as noted in last inspection. Perform required testing, seal & tag within 90 days. Re-inspection required | 1/9/2023 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces | Remove all non elevator related wiring from machine room, including coaxial cable & power for tv in adjacent room | 1/9/2023 | ||
| A17.1-1996 : Elevators | 2.8 - Pipes, wiring, and ducts | 102.1 | Wiring for exhaust fan in machine room shall be made permanent, be grounded & be properly enclosed in conduit per NFPA 70 | 1/9/2023 | ||
| A17.1-1996 : Elevators | 2.8 - Pipes, wiring, and ducts | 102.1 | Remove unused wiring connected to exhaust fan switch in machine room or use power fan in accordance with NFPA 70 | 1/9/2023 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Phone failed to operate | 1/9/2023 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of current state operating certificate shall be properly displayed in machine room | |||
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1002.2g (Standby Power Operation) | x | Emergency recovery lowering device is inoperable. repair and reinspect 3.26.10 |