Inspection
Inspection Details
Equipment ID
14969
14969
Inspection Date
7/3/2019
7/3/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Vernon Livergood
Vernon Livergood
Mechanic Name
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
84903ba9-fecb-4d9f-9a7a-9a32840d1088
84903ba9-fecb-4d9f-9a7a-9a32840d1088
Location
Jackson County Family Courts
625 E 26TH ST, KANSAS CITY, MO
625 E 26TH ST, KANSAS CITY, MO
Owner
Jackson County Family Courts
625 E 26TH ST, KANSAS CITY, MO 64108-2719
625 E 26TH ST, KANSAS CITY, MO 64108-2719
Billing
Attn: Jackson County Family Courts
625 E 26TH ST, KANSAS CITY, MO 64108-2719
625 E 26TH ST, KANSAS CITY, MO 64108-2719
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | do not store non-elevator related material in the machine room | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | the alarm bell did not work on battery power | 7/12/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | open egg crate ceiling panels, light tubes shall be guarded | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | emergency phone did not work, no dial tone | 7/12/2021 |
| MO Minimum : Elevators | (K) - Car Platforms and Car Slings | (K)4 | No | No | does not have crosshead data tag | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | escape hatch is not secured, missing the wing nuts | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)6 | No | No | The tank is not marked #5 | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | do not store non elevator related material in the machine room | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | the emergency phone did not work | 8/17/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | the elevator has open egg crate drop ceiling panels, the light tubes shall be guarded to prevent breakage | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | escape hatch is not secured from being opened from inside the elevator, the wing nuts are missing | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | does not have a crosshead data tag, provide a crosshead data tag | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | could not find the breaker for the elevator cab 110 volt circuit, find the location of the disconnect and make a sign with the location and hang sign in the machine room | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | adjust the door restrictor, the hook did not catch | 6/5/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | emergency phone is not working, fix the emergency phone | 6/5/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Getting wiring traced to install phone system (has working bell) | 6/5/2024 |