Inspection
Inspection Details
Equipment ID
14616
14616
Inspection Date
7/8/2019
7/8/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Michael Loftin
Michael Loftin
Relief Valve Pressure
580
580
Slide
Governor Rope Pull
Door Closing Force
18
18
External ID
7644ece9-8bc2-4aaf-8fa7-14a9a3d44df3
7644ece9-8bc2-4aaf-8fa7-14a9a3d44df3
Location
Ozark High School
1350 W BLUFF DR, OZARK, MO
1350 W BLUFF DR, OZARK, MO
Owner
Ozark R-VI School District
PO BOX 166, OZARK, MO 65721-0166
PO BOX 166, OZARK, MO 65721-0166
Billing
Attn: Ozark R-VI School District
PO BOX 166, OZARK, MO 65721-0166
PO BOX 166, OZARK, MO 65721-0166
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | needs curent certifivcate posted in machine room | 8/15/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Operating Certificate expired 12/2018 | 7/8/2025 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | Machine Room Fire Extinguisher shall have current monthly/annual test tag. (Expired ) | 7/8/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Cab lighting shall be guarded. | 7/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine Room Fire Extinguisher shall have current monthly/annual test tag. (Expired ) 2020/2021 repeat violation | 7/8/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | B(8) Cab lighting shall be guarded. 2020/2021 repeat violation | 7/8/2025 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | Machine Room Fire Extinguisher shall have current monthly/annual test tag. (Expired ) | 4/7/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Cab lighting shall be guarded. | 4/7/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine Room Fire Extinguisher shall have current monthly/annual test tag. (Expired ) 2020/2021 repeat violation | 4/7/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | B(8) Cab lighting shall be guarded. 2020/2021 repeat violation | 4/7/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency/auxiliary lighting shall work with power loss. 1 of 2 bulbs not working, battery weak (REINSPECTION > 6/13/22) | 1/6/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | B(8) Cab lighting flickering and very Dim | 7/8/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 7/8/2025 |