Inspection
Inspection Details
Equipment ID
6199
6199
Inspection Date
6/25/2019
6/25/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dixon Liljegren
Dixon Liljegren
Mechanic Name
William Stein
William Stein
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
26
26
External ID
89be3252-b65a-465e-a558-3a614b59434e
89be3252-b65a-465e-a558-3a614b59434e
Location
McClain Hall
100 E NORMAL ST, KIRKSVILLE, MO
100 E NORMAL ST, KIRKSVILLE, MO
Owner
Truman State University
100 E NORMAL ST, KIRKSVILLE, MO 63501
100 E NORMAL ST, KIRKSVILLE, MO 63501
Billing
Attn: Truman State University-Physical Plant Office
100 E NORMAL ST, KIRKSVILLE, MO 63501
100 E NORMAL ST, KIRKSVILLE, MO 63501
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Remove scavenger pump from elevator pit. | 11/28/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Provide self locking mechanism for machine room door. | 11/28/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.10 - Numbering of elevators, machines, and disconnect switches | 8.11.2.1.2(j) | No | No | Provide feed source for main line disconnect. | 11/28/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.10 - Numbering of elevators, machines, and disconnect switches | 8.11.2.1.2(j) | No | No | Provide feed source for 110V car light disconnect. | 11/28/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Fire recall module in machine room missing cover. | 11/28/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Provide pit container for oil collection in pit not to exceed 5 gallon capacity. | 11/28/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Provide self locking mechanism for machine room door. | 8/3/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.10 - Numbering of elevators, machines, and disconnect switches | 8.11.2.1.2(j) | No | No | Label main line disconnect feed source, panel and breaker. 2.8 | 8/3/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.10 - Numbering of elevators, machines, and disconnect switches | 8.11.2.1.2(j) | No | No | Label 110VAC car light disconnect feed source, panel and breaker. 2.8 | 8/3/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Fire recall module in machine room missing cover. | 8/3/2022 |
| A17.1-2016 : Elevators | 5.15 - Overspeed Valve | 8.6.5.16.5 | No | No | OSV valve not tested at time of inspection. Reinspection required for certificate. | 11/28/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Remove padlock from machine room door, and provide a self locking mechanism for machine room door. | 7/8/2024 |