Inspection
Inspection Details
Equipment ID
22489
22489
Inspection Date
7/11/2019
7/11/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Thomas Kitzinger
Thomas Kitzinger
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
20
20
External ID
69a01bbd-b490-4565-a5fb-4fe08cb6e4bc
69a01bbd-b490-4565-a5fb-4fe08cb6e4bc
Location
Arcade Building
816 OLIVE ST, SAINT LOUIS, MO
816 OLIVE ST, SAINT LOUIS, MO
Owner
Attn: UNK
Dominium Management Services
2905 NORTHWEST BLVD STE 150, PLYMOUTH, MN 55441
Phone: (314) 492-3994
Dominium Management Services
2905 NORTHWEST BLVD STE 150, PLYMOUTH, MN 55441
Phone: (314) 492-3994
Billing
Attn: UNK
Dominium Management Services
2905 NORTHWEST BLVD STE 150, PLYMOUTH, MN 55441
Phone: (314) 492-3994
Email: jenni.feder@dominiuminc.com
Dominium Management Services
2905 NORTHWEST BLVD STE 150, PLYMOUTH, MN 55441
Phone: (314) 492-3994
Email: jenni.feder@dominiuminc.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11 Periodic Inspection and Test. | Yes | No | TESTING INCOMPLETE due to Maint Co. scheduling conflicts and issues. REMAINING: all weight tests, buffer tests, slide, | 9/30/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current State Operating Permit, expired | 4/11/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Not Present: MCP, Testing procedures, Fire service log, | 4/11/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | In car "Help button" pushed in, repair and test phone. | 9/30/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.5 - Access to Hoistway | 8.6.4.14 Hoistway Access Switches | No | No | Hoistway access switch at top landing non-functional, Repair. | 4/11/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 8.11.2.1.3(cc) | No | No | [1001.2(c)(29)]//8.6.1.6.2 : Hoist Ropes appear dry and showing “rouge”. Ropes shall be cleaned and lubricated per OEM recommendations. ( ) | 4/11/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | No | No | I(1) : Excessive debris in pit (combustible hazard) | 4/11/2023 |
| A17.1-2016 : Elevators | 1.15 - sign and operating device symbols | 8.6.1.6.7 | No | No | There are no 5 year test tags on elevator equipment. Have elevator company performed 5 year test to tag equipment | 4/11/2023 |
| A17.1-2016 : Elevators | 3.3 - Top-of-car operating device | 8.11.2.1.3(c) | No | No | Car top inspection does not work | 4/11/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11 Periodic Inspection and Test. | Yes | No | There are no 5 yr test tags on elevator equipment. Re-inspection required | 8/15/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.3 - Top-of-car operating device | 8.11.2.1.3(c) | Yes | No | Car top inspection station does not work, needs repair. Re-inspection required Rule 2.26. 1.4.1 (A) | 11/15/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 8.11.2.1.3(cc)(1) Wire ropes shall be replaced | Yes | Yes | Elevator has broken suspension cable, replace all cables. Red tagged, Re-inspection required Rule 8.6.3.2 | 11/15/2022 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Governor rope has slight damage on one lay and needs to be replaced. Re-inspection required | 2/24/2026 |