Inspection
Inspection Details
Equipment ID
14391
14391
Inspection Date
7/1/2019
7/1/2019
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
Thomas Jimas
Thomas Jimas
Relief Valve Pressure
Slide
12 5/8"
12 5/8"
Governor Rope Pull
230/630
230/630
Door Closing Force
18.5
18.5
External ID
3d627c0d-a333-48de-a6a5-abb950b5d80b
3d627c0d-a333-48de-a6a5-abb950b5d80b
Location
Central Downtown Parking Garage
707 PINE ST, SAINT LOUIS, MO
707 PINE ST, SAINT LOUIS, MO
Owner
St. Louis, City of- Treasurer's Office
133 S 11TH ST STE 520, SAINT LOUIS, MO 63102-1135
133 S 11TH ST STE 520, SAINT LOUIS, MO 63102-1135
Billing
Attn: City of St. Louis
133 S 11TH ST STE 520, SAINT LOUIS, MO 63102-1135
133 S 11TH ST STE 520, SAINT LOUIS, MO 63102-1135
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Emergency light and alarm bell not working. | 7/1/2019 |
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | Yes | No | Restricted opening inoperative. | 8/7/2019 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency bell inoperative. | 8/7/2019 |
| A17.1-1996 : Elevators | 2.10 - Numbering of elevators, machines, and disconnect switches | 1001.2(b)(10) | No | No | Mark car number on car top and corresponding number on machine room governor. | 11/20/2019 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in elevator cab does not work. | 7/16/2020 |
| A17.1-1996 : Elevators | 2.42 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater) | 8.4.10.1.2 - Protection not functioning | Yes | No | Seismic feature not working correctly, repair as needed. | 8/4/2023 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Existing emergency phone not working correctly, repair as needed. | 8/4/2023 |
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | Yes | No | Door restrictor is out of adjustment, repair as needed. | 8/4/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept clean. Remove excess debris. | 3/28/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Adjust upthrust roller bearings for proper clearance to door hangar track (multiple floors). | 3/28/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | This test is incomplete. The following items still need to be tested: COP stop switch on fire service recall (no key available), all weight portions of the test (125% & 100%), buffers, and slide. | 2/8/2024 |