Inspection
Inspection Details
Equipment ID
8743
8743
Inspection Date
7/12/2019
7/12/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Bobby Joe Mehrens
Bobby Joe Mehrens
Relief Valve Pressure
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
28
28
External ID
10952ca2-6a9c-45c5-b480-7b10ef818292
10952ca2-6a9c-45c5-b480-7b10ef818292
Location
Village East Towers LTD
1218 VILLAGE DR, SAINT JOSEPH, MO
1218 VILLAGE DR, SAINT JOSEPH, MO
Owner
Village East Towers LTD
1218 VILLAGE DR, SAINT JOSEPH, MO 64506-2477
1218 VILLAGE DR, SAINT JOSEPH, MO 64506-2477
Billing
Attn: Village East Towers LTD
1218 VILLAGE DR, SAINT JOSEPH, MO 64506-2477
1218 VILLAGE DR, SAINT JOSEPH, MO 64506-2477
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 8.11.2.1.3(r) | No | No | Install covers on 4x4 electrical gangboxes at top of hoistway | 2/22/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.27 - Crosshead data plate | 8.11.2.1.3(k) | No | No | Install suspension rope data tag to ropes | 2/22/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | Car door restrictor does not function. | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 8.11.2.1.3(r) | No | No | Install covers on conduit pullboxes located near top of hoistway. | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.11.1 | No | No | Test and log firefighter operation monthly | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.9 - Guarding of exposed auxiliary equipment | 2.10.1 | No | No | Provide guarding of machine drive sheave and hoist ropes. | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.16 - Rated load, platform area, and data plate | 2.16.3.1 Capacity Plates | No | No | Install 2500 LBS Capacity plate inside the elevator. The existing capacity plate does not correspond with crosshead data plate. | 6/21/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.16 - Rated load, platform area, and data plate | 2.16.3.1 Capacity Plates | No | No | Install capacity plate inside the elevator "2000 lbs Capacity" | 11/13/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | No | No | Machine room access door shall be self-closing | 11/13/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | Car door restrictor does not function | 5/16/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.7.2 Periodic Test Record (Test Tags) | No | No | Install and date period test tag | 11/13/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.8 - Door closing force | 2.13.4.2.3 | Yes | No | REDUCE DOOR TORQUE TO LESS THAN 30lbs | 10/10/2025 |