Inspection
Inspection Details
Equipment ID
20347
20347
Inspection Date
6/20/2019
6/20/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Bill Suedkamp
Bill Suedkamp
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
27
27
External ID
bb6c2fb0-6fa9-4f94-84c7-9c180e15652f
bb6c2fb0-6fa9-4f94-84c7-9c180e15652f
Location
Henrick's BBQ
1200 S MAIN ST, SAINT CHARLES, MO
1200 S MAIN ST, SAINT CHARLES, MO
Owner
Attn: UNK
Hendrick's BBQ
1200 S MAIN ST, SAINT CHARLES, MO 63301
Phone: (000) 000-0000
Email: chef@mgoodcompanystl.com
Hendrick's BBQ
1200 S MAIN ST, SAINT CHARLES, MO 63301
Phone: (000) 000-0000
Email: chef@mgoodcompanystl.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Provide code compliant machine room lighting. | 9/6/2018 |
| conversion | conversion | n/a | No | No | Provide a complete set of controller prints. | 9/6/2018 |
| conversion | conversion | n/a | No | No | Provide a maintenance control program. | 9/6/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide on-site maintenance documents. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.11.2.1.2(e) (Re-Inspection) | No | No | The machine room shall not be used for storage of non-elevator related materials. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | No | No | The pit lighting shall be operational. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.2 - Stop switches | 8.11.2.1.1(b) (Re-Inspection) | No | No | The in car stop switch shall be keyed. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.11.2.1.2(g) | No | No | A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | The pit shall be cleaned. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.2 - Hoistway doors | 8.6.4.13 | No | No | Fire tabs are missing on the bottom of all hoistway doors. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | No | No | Lighting is required in the elevator pit. |