Inspection
Inspection Details
Equipment ID
8400
8400
Inspection Date
7/26/2019
7/26/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Bryan Henson
Bryan Henson
Relief Valve Pressure
285
285
Slide
Governor Rope Pull
Door Closing Force
14
14
External ID
628289bc-680f-4a6b-ace3-b1935c852950
628289bc-680f-4a6b-ace3-b1935c852950
Location
US Bank- Joplin
402 MAIN ST, JOPLIN, MO
402 MAIN ST, JOPLIN, MO
Owner
Attn: US BANK
US BANK
3640 S NOLAND RD STE 200, INDEPENDENCE, MO 64055
Phone: (816) 521-3387
Email: Amy.berger@usbank.com
US BANK
3640 S NOLAND RD STE 200, INDEPENDENCE, MO 64055
Phone: (816) 521-3387
Email: Amy.berger@usbank.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | pit has water & oil standing pit needs to be dry and clean | 3/30/2020 |
| conversion | conversion | n/a | No | No | needs current certificate posted in machine room | 3/30/2020 |
| conversion | conversion | conversion - reinspect | Yes | No | telephone not working--REINSPECT REQUIRED | 7/23/2018 |
| conversion | conversion | n/a | No | No | pit light not working | 3/30/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | No | No | I-1 Mo Min pit needs to be dry and clean | 3/30/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Telephone will not call out-52 volts on line | 7/26/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 1/7/21 : 2-way communication device shall work and give proper location | 9/25/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | 1/7/21 : Phase 2 switch not working. Repair/Replace REINSPECTION REQUIRED (14days) | 9/25/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | 1/7/21 Pit shall be kept dry. Remove rust from pit channels, repaint, repair water leak. | |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | 1/7/21 Pit light shall work | |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | 1/7/21 Pit Ladder shall be installed | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Must Post current state operating Cert. 5.100(2) | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Pit must be kept free of Water 8.6.4.7 | |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | Must provide permatly installed pit ladder. (I)5 | |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Must make Emergency Phone operable. 8.6.4.15 | 8/22/2024 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Pit Must be kept free of water ( currently 1" standing water in pit). 8.6.4.7 | |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | Must provide perminently installed pit ladder. (I)5 | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.11.2.2.6 Fire Fighters Operation (Re-Inspection) | Yes | No | Must make Car return to proper land after turning off Phase two Key switch. 6.4 |