Inspection
Inspection Details
Equipment ID
1358
1358
Inspection Date
7/16/2019
7/16/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Derek Rankin
Derek Rankin
Mechanic Name
Tom Worsham
Tom Worsham
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
a8c0fa83-a6ee-4eed-bb72-50a80f6c9ba1
a8c0fa83-a6ee-4eed-bb72-50a80f6c9ba1
Location
New Life Evangelistic Center
1411 LOCUST ST, SAINT LOUIS, MO
1411 LOCUST ST, SAINT LOUIS, MO
Owner
Attn: New Life Evangelistic Center
New Life Evangelistic Center
1411 LOCUST ST, SAINT LOUIS, MO 63103
Phone: (314) 399-1551
Email: solarjeff12@gmail.com
New Life Evangelistic Center
1411 LOCUST ST, SAINT LOUIS, MO 63103
Phone: (314) 399-1551
Email: solarjeff12@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)1 | x | x | SAFETIES BROKEN DURING CAT 5 TEST | 12/12/2018 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | NO VALID OPERATING CERTIFICATE POSTED | 2/7/2019 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine room door shall be self closing and self locking. | 2/7/2019 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)3 | Gutter water line running over top of controller. | 2/7/2019 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Machine room lights need to be anchored to ceiling and protective tubes over lights. | 2/7/2019 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Fire extinguisher needs to be in machine room. | 2/7/2019 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | Light switch cover needs to be installed. | 2/7/2019 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Clean machine room of all dirt and debris. | 2/7/2019 | ||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)2 | Drum machine needs to be resocketed. Reinspection required. | |||
| MO Minimum : Elevators | (I) - Pits | (I)7 | There is no stop switch in the pit. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No maintenance records on site. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency alarm does not work. | 7/6/2022 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency light does not work. | 7/6/2022 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Car lighting does not work. | 7/6/2022 | |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | There is a broken traveling cable zip tied together. | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current operating certificate in machine room. |