Inspection
Inspection Details
Equipment ID
11350
11350
Inspection Date
7/17/2019
7/17/2019
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Clyde Johnson
Clyde Johnson
Mechanic Name
Robert Kehm
Robert Kehm
Relief Valve Pressure
Slide
13
13
Governor Rope Pull
230/600
230/600
Door Closing Force
20
20
External ID
b7cdfa12-fe89-49e9-b63d-69c8e24e9552
b7cdfa12-fe89-49e9-b63d-69c8e24e9552
Location
Scottrade
700 MARYVILLE CENTRE DR, SAINT LOUIS, MO
700 MARYVILLE CENTRE DR, SAINT LOUIS, MO
Owner
Scottrade Inc
PO BOX 31759, SAINT LOUIS, MO 63131-0759
PO BOX 31759, SAINT LOUIS, MO 63131-0759
Billing
Attn: Scottrade Inc.
PO BOX 31759, SAINT LOUIS, MO 63131-0759
PO BOX 31759, SAINT LOUIS, MO 63131-0759
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | suspension ropes are starting to rouge and are below minimum diameter. Replace suspension ropes | 6/24/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Wording is missing from phase 1 key switch. Key shall be marked bypass off and on | 10/22/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Place current state operating certificate in elevator machine room | 10/22/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone inoperative Repair as necessary | 9/21/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Perform emergency power generator test to complete testing | 9/21/2024 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Wording is missing from phase 1 key switch. Key shall be marked bypass, off and on | 9/21/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Emergency power shall be tested. | 9/21/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Elevator cab phone does not work, phone line has no power. Re-inspection required | 8/3/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency bell is inoperable. Re-inspection required | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Yes | No | Emergency light is inoperable. Re-inspection required |