Inspection
Inspection Details
Equipment ID
841
841
Inspection Date
8/1/2019
8/1/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Bryan Henson
Bryan Henson
Relief Valve Pressure
500
500
Slide
Governor Rope Pull
Door Closing Force
20
20
External ID
0fe00060-9baf-4e74-b65c-b11f09808db5
0fe00060-9baf-4e74-b65c-b11f09808db5
Location
Cobblestone Village
2865 S INGRAM MILL RD, SPRINGFIELD, MO
2865 S INGRAM MILL RD, SPRINGFIELD, MO
Owner
Cobblestone Village
2865 S INGRAM MILL RD, SPRINGFIELD, MO 65804-4088
2865 S INGRAM MILL RD, SPRINGFIELD, MO 65804-4088
Billing
Attn: Cobblestone Village
2865 S INGRAM MILL RD, SPRINGFIELD, MO 65804-4088
2865 S INGRAM MILL RD, SPRINGFIELD, MO 65804-4088
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No records | 9/14/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Machine door to be self closing/locking | 9/14/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Phone failed | 9/28/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated certificate | 9/14/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Clean Machine Room | 11/14/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean pit | 11/14/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Must Post current State Cert. in Mach. room. 5.100.(2) | 1/13/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Must repair/replace broken Fire Service Phase I Key Switch Faceplate.211.8 | 10/4/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Fire service Phase I failed to operate | 11/9/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone failed to operate | 11/9/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone not working (not dialing out). | 3/10/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Fire Service Phase 1 key switch needs replaced. | 3/10/2023 |