Inspection
Inspection Details
Equipment ID
16756
16756
Inspection Date
7/22/2019
7/22/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Clyde Johnson
Clyde Johnson
Mechanic Name
Robert Kehm
Robert Kehm
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
37f8bd9d-f9d2-493d-a879-f6dc09dedec7
37f8bd9d-f9d2-493d-a879-f6dc09dedec7
Location
Convention Center
600 N 6TH ST, SAINT LOUIS, MO
600 N 6TH ST, SAINT LOUIS, MO
Owner
Attn: Metro Accounts Payable
Metro Accounts Payable
707 N 1ST ST, SAINT LOUIS, MO 63102
Phone: (314) 982-1400
Email: sbbrasfield@metrostlouis.org
Metro Accounts Payable
707 N 1ST ST, SAINT LOUIS, MO 63102
Phone: (314) 982-1400
Email: sbbrasfield@metrostlouis.org
Billing
Attn: Metro Accounts Payable
Metro Accounts Payable
PO BOX 1349, SAINT LOUIS, MO 63188
Phone: (314) 982-1400
Email: sbbrasfield@metrostlouis.org
Metro Accounts Payable
PO BOX 1349, SAINT LOUIS, MO 63188
Phone: (314) 982-1400
Email: sbbrasfield@metrostlouis.org
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Demarcation lights out top & bottom | 1/17/2019 |
| conversion | conversion | n/a | No | No | Top right comb plate missing | 1/17/2019 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(B) | No | No | Replace bad key switch. | 1/17/2019 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(L) | No | No | Replace handrail guides on both sides at the top of escalator. | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(H) | No | No | Repair both top and bottom demarcation lights. | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Need maintenance control program on site and posted on controller | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.5 Escalator or Moving Walk Startup | No | No | Screws on balustrade trim have to be flushed smooth cannot protrude as snag hazard | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.5.2(i) Demarcation lighting | Yes | No | Upper and lower demarcation lights not working | 6/1/2021 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.14 Escalator Entrance and Egress Ends | No | No | Machine space covers top and bottom rendered unoperateable | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Provide a maintenance control program | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(D) | No | No | Replace broken step tread | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(F) | No | No | Repair or replace damaged balustrade panel (top right side) also several other panels need to be aligned correctly | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.11.4.2.10 Escalator Missing Step or Pallet Device | Yes | Yes | Missing step switch does not work. Red-tagged and removed from service. Re-inspection required | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.3 Step/Skirt Performance Index | Yes | No | Need to perform step indexing test. Re-inspection required |