Inspection
Inspection Details
Equipment ID
10279
10279
Inspection Date
10/12/2018
10/12/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Relief Valve Pressure
490
490
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
47e79368-a0c9-4b6e-ab54-fd7be9b286a9
47e79368-a0c9-4b6e-ab54-fd7be9b286a9
Location
Uncle Bob's Self-Storage
11540 SAINT CHARLES ROCK RD, BRIDGETON, MO
Phone: (314) 219-1682
11540 SAINT CHARLES ROCK RD, BRIDGETON, MO
Phone: (314) 219-1682
Owner
Life Storage
6467 MAIN ST, WILLIAMSVILLE, NY 14221-5856
6467 MAIN ST, WILLIAMSVILLE, NY 14221-5856
Billing
Attn: Life Storage
6467 MAIN ST, WILLIAMSVILLE, NY 14221-5856
6467 MAIN ST, WILLIAMSVILLE, NY 14221-5856
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Provide monthly fire service test & document on log in machine room | 12/17/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Replace missing section or false ceiling in car enclose florescent bulbs in tubes | 12/17/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 12/2/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service test & document on log in machine room | 12/2/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Repair emergency light in the car | 11/19/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove water in pit | 12/2/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Repair car door. Electrical reopening device missing reflector | 12/2/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)6 | No | No | Repair car door, Electrical re-opening device missing reflector | 1/6/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Place current state operating certificate in elevator machine room | 8/21/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | Overspeed valve due for full load test and tripping speed checked | 6/20/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 9/7/2023 |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 8.10.3.3.2(p) | Yes | No | Each elevator cab shall be provided with two lamps of equal illumination. There is only one operating lamp in the cab. | 5/12/2025 |