Inspection
Inspection Details
Equipment ID
2046
2046
Inspection Date
7/19/2019
7/19/2019
Inspection Type
Reinspection
Reinspection
Inspector Name
Dixon Liljegren
Dixon Liljegren
Mechanic Name
Ronald Dennison
Ronald Dennison
Relief Valve Pressure
0
0
Slide
Governor Rope Pull
Door Closing Force
0
0
External ID
b90f66d8-178e-4cbb-aceb-ad51614ff60a
b90f66d8-178e-4cbb-aceb-ad51614ff60a
Location
Lee's Summit High School
400 SE BLUE PKWY, LEES SUMMIT, MO
Phone: (816) 986-2000
400 SE BLUE PKWY, LEES SUMMIT, MO
Phone: (816) 986-2000
Owner
Attn: Lee's Summit R-7 School District
Lee's Summit R-7 School District
502 TRANSPORT DR, LEES SUMMIT, MO 64081
Phone: (816) 986-2181
Email: matthew.tillman@lsr7.net
Lee's Summit R-7 School District
502 TRANSPORT DR, LEES SUMMIT, MO 64081
Phone: (816) 986-2181
Email: matthew.tillman@lsr7.net
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Overhead lighting in car is unguarded. | |||
MO Minimum : Elevators | (K) - Car Platforms and Car Slings | (K)6 | Guide roller under car badly cracked and deteriorating. | |||
MO Minimum : Elevators | (G)2-Alterations | 8.7.2.14.2 Car Enclosure | x | Emergency lights not working. | 1/19/2021 | |
MO Minimum : Elevators | (G)2-Alterations | 8.7.2.14.2 Car Enclosure | x | Emergency alarm not working. | 1/19/2021 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Fan guard on ceiling not secured well enough, and hanging down. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | x | Door reopening devices not working. | 8/20/2021 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | x | Sheet metal skins on car doors coming loose, repair. | 8/20/2021 | |
A17.1-2016 : Elevators | 1.16 - Rated load, platform area, and data plate | 2.16.3 | x | no metal data tags | 1/19/2022 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | x | car lts not guarded | 1/19/2022 | |
MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Remove all non elevator related items from machine room. | |||
A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.11.3.1.1(r) | x | Provide door restrictor on car doors. | 1/18/2023 | |
MO Minimum : Elevators | (I) - Pits | (I)7 | Pit switch not accessible from landing, move closer to the door. | |||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light switch is red in color. Change to black or white to avoid further confusion and safety. | |||
A17.1-2016 : Elevators | 2.14 - Code data plate | 8.11.2.1.2(hh) | Provide code data plate in machine room. | |||
A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 8.11.2.1.2(k) | Smoke detector in machine room has paint cover on it. | |||
MO Minimum : Elevators | (I) - Pits | (I)7 | Pit stop switch hidden, relocate for clear identification. | |||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light switch is red in color, change to black or white to avoid confusion. | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Remove all non elevator related items from machine room. | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | Provide covers for FFS modules in machine room. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working, alarm bell ok. | 9/27/2023 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | x | Provide door restrictors on both car doors. | 9/27/2023 | |
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working. Line? | 4/1/2024 | |
A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | x | Shunt trip not overriding emergency battery lowering. Need relay added | 4/1/2024 | |
A17.1-2016 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | Machine room door must be self-closing and self-locking | |||
A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.4.19.6 | x | Top hoistway smoke sensor recalls elevator to wrong floor. Need relay added | 4/1/2024 | |
A17.1-2016 : Elevators | 3.17 - Door and gate equipment | 8.6.4.13 | Car door needs new leading edge stainless steel wrap around skin. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working on DC power, alarm bell ok. |