Inspection
Inspection Details
Equipment ID
18095
18095
Inspection Date
8/19/2019
8/19/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Derek Rankin
Derek Rankin
Mechanic Name
Bill Suedkamp
Bill Suedkamp
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
7bfc600a-6b25-435c-8ea6-7644f4b03239
7bfc600a-6b25-435c-8ea6-7644f4b03239
Location
America's Center
701 CONVENTION PLZ, SAINT LOUIS, MO
Phone: (314) 342-5036
701 CONVENTION PLZ, SAINT LOUIS, MO
Phone: (314) 342-5036
Owner
Attn: America's Center
America's Center
701 CONVENTION PLZ, SAINT LOUIS, MO 63101
Phone: (314) 342-5118
America's Center
701 CONVENTION PLZ, SAINT LOUIS, MO 63101
Phone: (314) 342-5118
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.11.4.2.13 | No | No | Both handrails have cracks and need to be replaced. Reinspection required. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | Pits need cleaning. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.11.4.2.13 | No | No | Both handrails have cracks and need to be replaced. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.19 - Maintenance records | 8.6.1.4 | No | No | Provide written maintenance records to be kept on site. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.11.4.1 (c) | No | No | Cracks in handrail,replace | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.19 - Maintenance records | 8.6.1.4 | No | No | Provide MCP | 3/18/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Provide comb impact test | 4/5/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.11.4.2.1 (Re-Inspection) | No | No | Upper pit light not working | 4/5/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.6.8.1 | No | No | The right and left side handrails have degraded and shall be replaced. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.7 - Combplate and comb step impact device | 8.6.8.4 Combplates | No | No | Comb plate is missing one tooth. Replace comb plate. | 3/18/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 8.11.4.2.13 | Yes | No | Both handrails have cracks and need to be replaced. Reinspection required. |