Inspection
Inspection Details
Equipment ID
10083
10083
Inspection Date
8/20/2019
8/20/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Clyde Johnson
Clyde Johnson
Mechanic Name
John Hambrough
John Hambrough
Relief Valve Pressure
520
520
Slide
Governor Rope Pull
Door Closing Force
25/20
25/20
External ID
85a70ba3-a460-4fed-9ccb-83202995245e
85a70ba3-a460-4fed-9ccb-83202995245e
Location
Brentwood Middle School
9127 WHITE AVE, BRENTWOOD, MO
Phone: (314) 962-3837
9127 WHITE AVE, BRENTWOOD, MO
Phone: (314) 962-3837
Owner
Attn: Francis Merrins
Brentwood School District
9127 WHITE AVE, BRENTWOOD, MO 63144
Phone: (314) 550-3804
Email: fmerrins@brentwoodmoschools.org
Brentwood School District
9127 WHITE AVE, BRENTWOOD, MO 63144
Phone: (314) 550-3804
Email: fmerrins@brentwoodmoschools.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certficate in machine room. | 10/20/2023 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 1/24/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Expired | |
| A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | Yes | No | Unsealed | 7/22/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | Sump hole filled with oil, remove. Determine if sump pump works, if not replace. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | None | |
| A17.1-1996 : Elevators | 2.10 - Numbering of elevators, machines, and disconnect switches | 211.9 | No | No | Existing inside Hoistway door numbering does not match door buck numbering. Confirm COP,door buck, and Hoistway doors all numbered same. | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Observed sump pump not working correctly, repair/replace as needed. | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Provide means to prevent accumulation of groundwater in the pit. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | Yes | No | OSV in pit is not sealed, provide testing. | 11/28/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in car has power, needs programming. | 11/28/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Provide existing battery backup lowering unit to work correctly. | 11/28/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | On Phase II operation, call cancel function not working correctly. Re-inspection required | 8/4/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Need to remove water from pit | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Need to provide working sump pump on pit | |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | No | No | Need to provide means to prevent ground water from entering pit | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Elevator phone is not working. Re-inspection required | 8/4/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | OSV is not sealed. Re-inspection required | 8/4/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Provide for pit light to work | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm in car is not working. Re-inspection required | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light in car does not work. Re-inspection required | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | Provide up-to-date wiring diagrams & maintenance records in maintenance control program | |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.3a(8) Visual and audible signal | Yes | No | Indicator for fire service phase I in car shall work, needs repaired. Re-inspection required | |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1002.2g (Standby Power Operation) | Yes | No | Emergency battery lowering device is not working, needs repaired. Re-inspection required | |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | On phase I operation, call cancel function is not working correctly. Re-inspection required | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room |