Inspection
Inspection Details
Equipment ID
20691
Inspection Date
9/10/2019
Inspection Type
Annual Inspection
Inspector Name
Michial Linenfelser
Mechanic Name
Thomas Moore
Relief Valve Pressure
460
Slide
Governor Rope Pull
Door Closing Force
19,19,19,20
External ID
0f379857-bd05-46a1-814d-247dc7fa5d4c
Location
St. Louis Art Museum
1 FINE ARTS DR, SAINT LOUIS, MO
Owner
Attn: Art Museum
St. Louis Art Museum
1 FINE ARTS DR, SAINT LOUIS, MO 63110
Phone: (000) 000-0000
Email: dave.perkins@slam.org
Violations
|
Code
|
Item
|
Section
|
Reinspection
|
Red Tag
|
Reason For Violation
|
Fixed Date
|
|
conversion
|
conversion
|
n/a
|
|
|
An electrical junction box, on top of the elevator car, is missing a cover with electrical wiring exposed. Replace cover to prevent accidental exposure to elevator and emergency personnel.
|
1/14/2019
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.14 - Hoistway clearances
|
8.11.2.1.3(t)
|
|
|
The electrical ductwork inside the hoistway is striking the elevator car doors when they are fully open not allowing hoistway access to work as required. Repair or replace ductwork to allow the elevator car doors to remain open when using the hoistway access feature.
|
10/12/2020
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.5 - Car lighting and receptacles
|
8.6.4.15 Emergency Lighting
|
x
|
|
The emergency car lighting is not operational, likely indicating that the back-up power device (battery) has failed. The fixture shall be repaired to operate. Reinspection required.
|
11/12/2020
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
|
|
The fire retaining tab is missing on the R2 hoistway door, reinstall missing tab on the bottom of the hoistway door.
|
6/28/2024
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
The LARGE emergency light fixture inside the elevator CEILING is not operational and shall be repaired. Reinspection required.
|
11/20/2023
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
|
|
There shall be maintenance records kept in the elevator machine room accessible to the inspector depicting dates and descriptions of maintenance tasks performed, callbacks, examinations, tests, adjustments, replacements and wiring diagrams. This shall be in accordance to the requirements in the Maintenance Control Program. Electronic means has NOT been approved by the State of Missouri.
|
12/4/2024
|