Inspection
Inspection Details
Equipment ID
22461
22461
Inspection Date
9/9/2019
9/9/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
Dustin Arnett
Dustin Arnett
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
19
19
External ID
cbf7d10f-6177-49d0-819c-6d0d3ab232f8
cbf7d10f-6177-49d0-819c-6d0d3ab232f8
Location
McGowan Brothers Development
1424 WASHINGTON AVE, SAINT LOUIS, MO
Phone: (314) 588-1170
1424 WASHINGTON AVE, SAINT LOUIS, MO
Phone: (314) 588-1170
Owner
McGowan Brothers Development
1307 WASHINGTON AVE, SAINT LOUIS, MO 63103-1926
1307 WASHINGTON AVE, SAINT LOUIS, MO 63103-1926
Billing
Attn: McGowan Brothers Development
Matthew
1307 WASHINGTON AVE, SAINT LOUIS, MO 63103-1926
Matthew
1307 WASHINGTON AVE, SAINT LOUIS, MO 63103-1926
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A maintenance control program shall be kept on-site. | 6/9/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Wiring schematics shall be kept on-site. | 6/9/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.11.2.1.2(g) | No | No | A currently tested ABC type fire extinguisher shall be located near the upper landing hoistway access entrance. | 6/9/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 8.11.2.1.3(cc) | No | No | A suspension rope data tag shall be installed that conforms to A17.1 2004 - 2.20.2.2 | 6/9/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 2.18.5 | No | No | A governor rope data tag shall be installed that conforms to A17.1 2004 - 2.18.5.3 | 6/9/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. | 6/1/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.28 - Counterweight and counterweight buffer | 2.22 | No | No | A counterweight runby sign shall be installed in the pit according to A17.1 2004 - 2.4.5 | 6/9/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.11.2.1.2(g) | No | No | A fire extinguisher shall be provided near the controller at the top floor. | 12/30/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.13 - Windows, projections, recesses, and setbacks | 8.11.2.1.3(s) | No | No | Landing sill guards shall be installed at the 1st and 3rd floors. | 12/30/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Maintenance control program (MCP) documentation shall be kept on-site. | 12/30/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Wiring schematics shall be kept on-site. | 12/30/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. | 4/1/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | The fire extinguisher is missing tag. Provide current tested and tagged ABC fire extinguisher. | 5/1/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | No one is answering the emergency phone. Take corrective action and re-test. | 5/29/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current State operating certificate shall be displayed in the control space in a non-combustible frame. | 2/11/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Fire extinguisher in hall near control space is out of date. Provide current up to date fire extinguisher. | 2/11/2026 |