Inspection
Inspection Details
Equipment ID
12637
12637
Inspection Date
9/9/2019
9/9/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
Dustin Arnett
Dustin Arnett
Relief Valve Pressure
500
500
Slide
Governor Rope Pull
Door Closing Force
29
29
External ID
8b7c58f0-ca90-4f0a-ae18-6b8f8aa0a6d7
8b7c58f0-ca90-4f0a-ae18-6b8f8aa0a6d7
Location
1914 LLC
1914 OLIVE ST, SAINT LOUIS, MO
Phone: (210) 355-9615
1914 OLIVE ST, SAINT LOUIS, MO
Phone: (210) 355-9615
Owner
Attn: 1914 LLC
1914 LLC
1914 OLIVE ST, SAINT LOUIS, MO 63103
Phone: (000) 000-0000
1914 LLC
1914 OLIVE ST, SAINT LOUIS, MO 63103
Phone: (000) 000-0000
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The machine room door shall be self closing and self locking. | |||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.3 Guards Between Adjacent Pits | The walk in pit door shall be self closing and self locking. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Debris in the machine room shall be removed. The machine room shall be kept clean. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Only items pertaining to the operation or maintenance of the elevator shall be stored in the machine room. All other items shall be removed. | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current state operating certificate is required. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | The machine room lighting shall be operational. | |||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | The pit lighting shall be operational. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The in cab emergency light shall be operational. | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The alarm bell shall operate on auxiliary power. | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.37 - Pressure Switch | 3.26.8 Pressure Switch | x | The lower pressure switch shall be operational. | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | A current fire extinguisher shall be provided in the machine room. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The in car emergency telephone shall be operational. | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.2.1 Phase 1 Emergency Recall OperationBy Fire Alarm initiating Devices | x | x | The machine room smoke detector shall be operational. (The smoke detector is currently covered in plastic) |