Inspection
Inspection Details
Equipment ID
16604
16604
Inspection Date
3/16/2018
3/16/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Relief Valve Pressure
540
540
Slide
Stopped Level
Stopped Level
Governor Rope Pull
NA / NA
NA / NA
Door Closing Force
29
29
External ID
Location
Rogers & Baldwin
313 South Ave, Springfield, MO
Phone: (417) 894-2425
313 South Ave, Springfield, MO
Phone: (417) 894-2425
Owner
Tillman, Scott
PO Box 550, Strafford, MO 65757
PO Box 550, Strafford, MO 65757
Billing
Attn: Scott Tillman
PO Box 550, , MO 65757
PO Box 550, , MO 65757
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Governor Rope required to be shorted | 7/20/2020 |
| conversion | conversion | conversion - reinspect | Yes | No | Jack has excessive oil leakage required to be replaced | 7/20/2020 |
| A17.1-2016 : Elevators | 2.36 - Hydraulic Cylinders | 8.6.5.5 Gland Packing and Seals | Yes | No | Jack seal required to be replaced | 3/14/2023 |
| A17.1-2016 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.5 | No | No | Scavenger pump in pit is required to be removed | 7/16/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Must post current State operating Cert. in Mach. Room 5.100(2) | 7/16/2025 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Pit must be kept free of oil 8.6.4.7 | 7/16/2025 |
| A17.1-2016 : Elevators | 2.36 - Hydraulic Cylinders | 8.6.5.5.2 Collection of Oil Leakage | No | No | Must provide means to monitor jack packing gland oil loss. (jack packing overflow tube routed back to pump unit with no means to monitor) | 7/16/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Mist provide Current annual test tag on Mach. room fir Extinguisher. 8.6.1.6.5 | 7/16/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Must preform and document Category 5 full load test. 8.6.1.7.2 | 2/27/2024 |
| A17.1-2016 : Elevators | 2.36 - Hydraulic Cylinders | 8.6.5.5 Gland Packing and Seals | Yes | No | Must repair/replace jack packing gland to limit oil leakage. 8.6.5.5 | 2/27/2024 |