Inspection
Inspection Details
Equipment ID
21023
21023
Inspection Date
9/24/2019
9/24/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Jeffrey Krug
Jeffrey Krug
Mechanic Name
Robert Suedkamp
Robert Suedkamp
Relief Valve Pressure
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
25
25
External ID
fa2d6598-f638-4d86-b9cf-e043d7b445fc
fa2d6598-f638-4d86-b9cf-e043d7b445fc
Location
Salvation Army Veterans Housing
2935 LOCUST ST, SAINT LOUIS, MO
Phone: (314) 652-3310
2935 LOCUST ST, SAINT LOUIS, MO
Phone: (314) 652-3310
Owner
Salvation Army- Divisional Headquarters
1130 HAMPTON AVE, SAINT LOUIS, MO 63139-3147
1130 HAMPTON AVE, SAINT LOUIS, MO 63139-3147
Billing
Attn: Salvation Army- Divisional Headquarters
1130 HAMPTON AVE, SAINT LOUIS, MO 63139-3147
1130 HAMPTON AVE, SAINT LOUIS, MO 63139-3147
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | AMaintenanceControlProgramforeachunit(see 8.6.1.1.1) shall be provided by the person(s) and/or firm maintaining the equipment and shall be viewable on- site by elevator personnel at all times from time of acceptance inspection and test or from the time of equip- ment installation or alteration | 8/1/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.27 - Crosshead data plate | 8.11.2.1.3(k) | No | No | Need crosshead data plate | 8/1/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.17 - Door and gate equipment | 8.11.2.1.3(w) | No | No | Safety Retainers missing from bottom of Hoistway doors.The top and bottom of horizontally sliding doors shall be provided with a means of retaining the closed door panel in position if the primary guiding means fail, | 8/1/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A written Maintenance Control Program shall be in place to maintain the equipment in compliance with the requirements of Section 8.6 | 8/1/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.17 - Door and gate equipment | 8.11.2.1.3(w) | No | No | 2.11.11.8 Bottom safety retainers missing from hoistway doors. The top and bottom of horizontally sliding doors shall be provided with a means of retaining the closed door panel in position if the primary guiding means fail. | 8/1/2023 |
| A17.1-2016 : Elevators | 3.23 - Suspension Means | 8.6.3.2 (Re-Inspection) | Yes | No | Hoist Ropes showing excessive rouge have stretched reducing diameter beyond maximum allowable amount. Replace hoist ropes. | 9/21/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Provide Crosshead Data Tag | 8/1/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Bottom safety retainers missing from hoistway doors. The top and bottom of horizontally sliding doors shall be provided with a means of retaining the closed door panel in position if the primary guiding means fail. | 1/17/2024 |
| A17.1-2016 : Elevators | 3.27 - Crosshead Data Plate and Rope Data Tags | 8.11.2.1.3(k) | No | No | Provide Crosshead Data Plate compliant with section 2.16.3 | 1/17/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The Emergency Phone in the car fails to establish two-way communication. | 10/8/2025 |