Inspection
Inspection Details
Equipment ID
16888
16888
Inspection Date
4/11/2018
4/11/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
Location
St. Louis Busch Stadium
700 Clark St, St. Louis, MO
Phone: (314) 345-9404
700 Clark St, St. Louis, MO
Phone: (314) 345-9404
Owner
St. Louis Cardinals LLC
700 Clark St, St. Louis, MO 63102
700 Clark St, St. Louis, MO 63102
Billing
Attn: St. Louis Cardinals LLC
700 Clark St, , MO 63102
700 Clark St, , MO 63102
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Comb impact guides are rusted and need to be tested to insure roper impact calibration. | 2/18/2019 |
| A17.1-1996 : Escalators | 7.9 - Steps and upthrust device | 802.5 | No | No | Repair broken step demarcation strip. | 3/29/2023 |
| A17.1-1996 : Escalators | 7.3 - Handrails | 802.2 | No | No | Repair left handrail that is cracked. | 3/29/2023 |
| A17.1-1996 : Escalators | 7.7 - Combplate and comb step impact device | 1206.6 | No | No | Comb impact guides are rusted. Pressure text on tripping pressure needed. Reinspect required within 30 days. | 3/29/2023 |
| A17.1-1996 : Escalators | 7.3 - Handrails | 802.2 | No | No | Right handrail is cracked. | 7/12/2023 |
| A17.1-1996 : Escalators | 7.7 - Combplate and comb step impact device | 802.6 | No | No | Replace broken step demarcations. | 7/12/2023 |
| A17.1-2016 : Elevators | 7.5 - Lighting | 8.6.11.6.2(i) | No | No | Bottom demarcation light does not work | 7/12/2023 |
| A17.1-1996 : Escalators | 7.6 - Caution Signs | 805.9 | No | No | Install deck cards and caution signs at top and bottom of the escalator and caution | 8/7/2024 |
| A17.1-1996 : Escalators | 7.3 - Handrails | 802.2 | No | No | Tighten main handrail chain | 8/26/2025 |
| A17.1-1996 : Escalators | 7.3 - Handrails | 802.2 | No | No | Adjust left side handrail tension | 8/26/2025 |
| A17.1-2016 : Elevators | 9.19 - Maintenance Records | 8.6.1.4.1(b)(2) | No | No | Record maintenance, call backs, repairs and testing in MCP . Give location of MCP on Controller | 8/26/2025 |
| A17.1-2016 : Elevators | 9.19 - Maintenance Records | 8.6.1.4.1(d) | No | No | Record Step/Skirt indexing graphs in 2025 MCP for permanent records of testing | 8/26/2025 |