Inspection
Inspection Details
Equipment ID
16333
16333
Inspection Date
9/11/2019
9/11/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James Mueller
James Mueller
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
440
440
Slide
Governor Rope Pull
Door Closing Force
27
27
External ID
aa2eb84a-0ab5-4fe5-9128-63d8d31a7927
aa2eb84a-0ab5-4fe5-9128-63d8d31a7927
Location
VT/AC
1964 PRAIRIE DELL RD, UNION, MO
Phone: (636) 583-5193
1964 PRAIRIE DELL RD, UNION, MO
Phone: (636) 583-5193
Owner
Attn: East Central College
East Central College
1964 PRAIRIE DELL RD, UNION, MO 63084
Phone: (636) 584-6735
Email: Julie.apperson@eastcentral.edu
East Central College
1964 PRAIRIE DELL RD, UNION, MO 63084
Phone: (636) 584-6735
Email: Julie.apperson@eastcentral.edu
Billing
Attn: East Central College
East Central College
1964 PRAIRIE DELL RD, UNION, MO 63084
Phone: (636) 584-6735
Email: Julie.apperson@eastcentral.edu
East Central College
1964 PRAIRIE DELL RD, UNION, MO 63084
Phone: (636) 584-6735
Email: Julie.apperson@eastcentral.edu
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Emergency phone not operating. | 7/26/2018 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | In car emergency telephone shall be operational. | 11/19/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lighting shall be operational. | 11/19/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Remove the abandoned electrical meter base in the machine room. | 12/5/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | 8.6.1.7.5 - The emergency lowering device (ERU) shall be operational. | 7/28/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | The car top GFCI has an open ground. | 7/28/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant maintenance control program (MCP) will be required no later than January 1, 2022. | 1/23/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 1/23/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | No | No | There are missing floor tiles inside the car. All passenger elevator car floors shall be maintained so that persons are not exposed to the hazards of tripping or falling. | 7/27/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Travel cable insulation damaged. Shall be properly repaired (not silver duct tape). | 12/5/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communication device shall work (with and without main power) and give proper location. The line is dead. | 10/6/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | No MCP is present in the machine room. A code compliant MCP shall be provided. | 12/5/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self-closing and self-locking. | 12/5/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Remove the abandoned electrical meter base in the machine room. | 12/5/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | 4x4 electrical box in machine room needs to have wiring inside box and cover installed. | 12/5/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 9/24/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 8/15/2025 |