MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6 General Maintenance Methods
|
No
|
No
|
The battery back–up lowering device was tested and did not operate as designed, the elevator failed to return to a lower floor and open its doors. Repair the device to operate as it is designed.
|
9/20/2021
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
No
|
No
|
The elevator pit light fixture did not work on the day of inspection, repair for proper illumination of the pit floor.
|
9/20/2021
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
No
|
No
|
The position indicating or “PI” device in the car was not operational on the day of inspection. Repair “PI” device to indicate the position of the elevator car.
|
10/28/2025
|
|
MO Minimum : Elevators
|
(O) - Existing Hydraulic Elevators
|
(O)4 (Re-Inspection)
|
Yes
|
No
|
The hydraulic pressure switch operation, on the elevator controller, will not perform as required when the oil pressure was decreased. The pressure switch operation shall be repaired to operate as required.
|
10/10/2023
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
Emergency phone in cab does not work. Re-inspection required
|
11/30/2023
|
|
MO Minimum : Elevators
|
(O) - Existing Hydraulic Elevators
|
(O)4 (Re-Inspection)
|
Yes
|
No
|
The hydraulic pressure switch operation, on the elevator controller will not perform as required when the oil pressure was decreased. The pressure switch operation shall be repaired to operate as required. Re-inspection required
|
11/30/2023
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
Two-Way communication is inoperable, and shall be repaired or replaced. Reinspection required.
|
10/28/2025
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
Yes
|
No
|
The inspection is incomplete due to electrical issues. Need to perform the following tests to complete inspection:2nd & top floors need tested, emergency lights, bell and phone, fire service, door pressures, battery lowering device. The relief pressure and the pit stop switch and bottom floor door are the only things that were tested. Re-inspection required
|
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
Two-Way communication is inoperable, and shall be repaired or replaced. Reinspection required.
|
|