Inspection
Inspection Details
Equipment ID
24586
24586
Inspection Date
10/11/2019
10/11/2019
Inspection Type
New Installation
New Installation
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
Jason Bunch
Jason Bunch
Relief Valve Pressure
Slide
UNK
UNK
Governor Rope Pull
UNK
UNK
Door Closing Force
UNK
UNK
External ID
ebe26b09-44c2-4335-97ec-6c8808ab3801
ebe26b09-44c2-4335-97ec-6c8808ab3801
Location
Ballpark Village Block 100 Office/Garage
4 Cardinal Way, St.Louis, MO
Phone: (314) 372-4568
Email: steven.mulligan@schindler.com
4 Cardinal Way, St.Louis, MO
Phone: (314) 372-4568
Email: steven.mulligan@schindler.com
Owner
Attn: Charlie Lee
Ballpark Village Holdings Block 100 Mixed Use, LLC
601 E Pratt St. 6th Floor, Baltimore, MD 21202
Phone: (410) 752-5444
Email: clee@cordish.com
Ballpark Village Holdings Block 100 Mixed Use, LLC
601 E Pratt St. 6th Floor, Baltimore, MD 21202
Phone: (410) 752-5444
Email: clee@cordish.com
Billing
Attn: Steve Mulligan
Schindler Elevator Corp
1926 Innerbelt Business Center Drive, St. Louis, MO 63114
Phone: (314) 372-4568
Email: steven.mulligan@schindler.com
Schindler Elevator Corp
1926 Innerbelt Business Center Drive, St. Louis, MO 63114
Phone: (314) 372-4568
Email: steven.mulligan@schindler.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.10 - Hoistway construction | 2.1 | Yes | No | Seal hoistway penetrations. | 10/16/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | Yes | No | Add second higher rated heat detector for shunt trip on 7th floor. | 10/16/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 2.7.5.1 | Yes | No | Provide 19 foot candles at the 7th floor control space. | 10/16/2019 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.8.2 | No | No | Unable to locate room with disconnect. Locate and test emergency lights and bell. | 11/25/2025 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters’ Emergency Operation: Operating Procedures (Signage) | No | No | Post Phase I instructions in lobby, near f/f switch. | 11/25/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Repair stuck door open and close buttons in front and rear car stations | 11/25/2025 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | Yes | No | Perform the annual emergency power operation testing on the elevators | 12/11/2024 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters’ Emergency Operation: Operating Procedures (Signage) | No | No | Post Phase I instructions near f/f switch in the lobby.. | 11/25/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Numerous buttons stuck/ sticking, replace as needed. | 11/25/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Provide testing of the elevator on emergency power. | 1/28/2025 |
| A17.1-2016 : Elevators | 4.12 - Standby power selection switch | 2.27.2 | Yes | No | Provide testing of the elevator emergency power selector switch (fire control room). | 1/28/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Provide existing alarm bell to work (both C O Ps). | 1/28/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Provide 125% brake test. | 1/28/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Car handrails ( both) missing, provide. | 11/25/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 11/25/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 11/25/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters' Emergency Operation: Operating Procedures | No | No | Need to post Phase I instructions near f / f switch in the lobby | 11/25/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Both car operating panels have stuck / sticking buttons. Repair or replace as needed | 11/25/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 3.26.10 (Auxiliary Power)(Re-Inspection) | Yes | No | Failed Cat 5 standby power test. Re-inspection required | 2/7/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.12 - Standby power selection switch | 2.27.2 | No | No | Need to provide testing of the elevator emergency power selector switch (fire control room). | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm bell not working (both COP's) Re-inspection required | 2/7/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Car handrails (both) are missing, need to replace | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Car handrails ( both) missing, provide. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Both car operating panels have stuck / sticking buttons. Repair or replace as needed | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters' Emergency Operation: Operating Procedures | No | No | Need to post Phase I instructions near f / f switch in the lobby | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters' Emergency Operation: Operating Procedures | No | No | Need to post Phase I instructions near f / f switch in the lobby | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Both car operating panels have stuck / sticking buttons. Repair or replace as needed | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Provide alarm bell to work (both COPs) Re-inspection required | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Car handrails ( both) missing, provide. |