Inspection
Inspection Details
Equipment ID
14768
14768
Inspection Date
10/17/2019
10/17/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
John Carpentier, Sr.
John Carpentier, Sr.
Relief Valve Pressure
370
370
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
5d516297-3b68-4a45-b07a-161ebe3424fd
5d516297-3b68-4a45-b07a-161ebe3424fd
Location
Oxford Hill Condominiums
10358 CHIMNEY ROCK DR, SAINT LOUIS, MO
Phone: (314) 799-1506
10358 CHIMNEY ROCK DR, SAINT LOUIS, MO
Phone: (314) 799-1506
Owner
Attn: Prism Realty
The Manor Condominiums
1033 Corporate Square Dr, SAINT LOUIS, MO 63132
Phone: (314) 966-1003
Email: prismrealty@yahoo.com
The Manor Condominiums
1033 Corporate Square Dr, SAINT LOUIS, MO 63132
Phone: (314) 966-1003
Email: prismrealty@yahoo.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Machine room light shall be guarded | 6/12/2026 |
| conversion | conversion | n/a | No | No | No current state operation certificate in elevator machine room. | 6/12/2026 |
| conversion | conversion | n/a | No | No | Car door closing force in excess of 30lbs | 6/12/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)12 (Door open zones) | No | No | car door restrictor does not work. | 10/17/2019 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | test phase 1 and 2 fire service. | 10/17/2019 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)6 | Yes | Yes | test life jacket type safety with full load. reinspection required. not a red tag. | 10/17/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Repair machine room lighting. | 6/12/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Secure gutter under piping in machine room (head clearance issue). | 6/12/2026 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Large electric junction box in hoistway is missing its cover. Reinstall. | 6/12/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Large head for floor leveling was torn off during stop ring test. No part of the car shall strike the overhead. | 12/3/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Test elevator cab phone. | 12/3/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Relocate car top selector tape bracket. Selector hits bracket when doing stop ring pressure test. | 6/12/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certificate in machine room | 8/1/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator. (Oil and rags in Pit) | 8/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | Replace missing Up Thrust on top landing hall door | 6/28/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Car shall have functioning Normal Terminal Limits actuating before Final Terminal Limit. | 8/1/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator. (Oil and rags in Pit) | 6/12/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Where pressure piping, valves, and cylinders use packing glands or seals, they shall be examined and maintained to prevent excessive loss of fluid. | 6/12/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency Phone in car fails to establish two-way communication | 5/15/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | The fire extinguisher in the machine room is due to be serviced or replaced. | 6/12/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | The fire extinguisher in the machine room is due to be serviced or replaced. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Replace machine room lighting to provide adequate illumination in the machine room | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The emergency phone connects, but the person answering cannot hear the person in the elevator. (Reinspect) |