Inspection
Inspection Details
Equipment ID
2321
2321
Inspection Date
4/27/2018
4/27/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Unknown Conversion
Unknown Conversion
Mechanic Name
Relief Valve Pressure
500
500
Slide
Governor Rope Pull
Door Closing Force
22
22
External ID
Location
Education Bldg-HU #9
3401 Faraon, St. Joseph, MO
Phone: (816) 387-2158
3401 Faraon, St. Joseph, MO
Phone: (816) 387-2158
Owner
WRDCC
3401 Faraon St, St. Joseph, MO 64506
3401 Faraon St, St. Joseph, MO 64506
Billing
Attn: WRDCC
3401 Faraon, , MO 64506
3401 Faraon, , MO 64506
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | Provide fire service instructions inside and outside elevator. | 6/13/2023 | ||
| conversion | conversion | n/a | elevator phone does not function. | 6/13/2023 | ||
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | Post firefighter phase 1 instructions next to hall fire keyswitch. Presently has phase 2 instructions next to hall fire service keyswitch. | 6/13/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | Cylinder drain lines run to hydraulic tank. Remove from tank and run to pit containers of no more than 5 gallons. | 6/13/2023 | ||
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | Post firefighter phase 1 instructions next to hall firefighter keyswitch, not phase 2 instructions. | 6/13/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | Cylinder drain lines run back to pumping unit. Cylinder drain lines need to be ran into pit collection containers. Each cylinder shall have a seperate collection container of no more than 5 gallon capacity. | 6/13/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | Post In Case of Fire signage next to hall button fixture at each landing | 6/13/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No MCP | 6/13/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No MRL on site | 6/13/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Machine room fire extinguisher certification has expired. | 6/13/2023 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | REMOVE ALL NON-ELEVATOR RELATED ITEMS FROM MACHINE ROOM | 8/8/2024 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | REMOVE NON-ELEVATOR RELATED ITEMS FROM MACHINE ROOM |