Inspection
Inspection Details
Equipment ID
10450
10450
Inspection Date
11/1/2019
11/1/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Carl Switzer
Carl Switzer
Relief Valve Pressure
270
270
Slide
Governor Rope Pull
Door Closing Force
n/a
n/a
External ID
a9b05cae-64a7-436b-adb7-193c94ac363f
a9b05cae-64a7-436b-adb7-193c94ac363f
Location
Darlington Mfg
1401 JUNGE BLVD, JOPLIN, MO
Phone: (471) 297-0555
1401 JUNGE BLVD, JOPLIN, MO
Phone: (471) 297-0555
Owner
Darlington Mfg
1401 JUNGE BLVD, JOPLIN, MO 64804
1401 JUNGE BLVD, JOPLIN, MO 64804
Billing
Attn: Darlington Mfg
1401 JUNGE BLVD, JOPLIN, MO 64804
1401 JUNGE BLVD, JOPLIN, MO 64804
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Problem in leveling both directions & cancelling calls--suspect relays | 7/12/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | No | No | sump not working and water in pit | 7/12/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.7 - Car leveling and anticreep devices | 8.11.2.1.3(j) | No | No | Elevator stops in leveling zone-will not level into floor--needs repaired | 7/12/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | sump pump cover needs to be put back in place | 7/12/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | machine room gate needs to be locked | 7/12/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | needs curreent certificate posted | 7/12/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | 203.8: Underside of wooden platforms shall be protected against fire, either appropriate steel or fire retardant paint. ( recoat previous paint for full coverage) | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | I(1)/106.1 Pit shall be kept dry. Remove rust from pit channels, repaint, repair water leak. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Provide operational emergency light and alarm | 3/29/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Provide operational light in pit | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Provide MCP in machine room | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | Yes | No | Pit floor shall be kept free of water, remove all rust from pit equipment and replace all rubber gaskets at each fittings 30 day reinspection | 3/29/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11.1.4(a) Elevators Placed in Inactive Status | Yes | Yes | Unit placed inactive , the owner does not use this unit because it only goes to 2 of the bldgs floors. They are planning on either modernizing on removing the unit next year | 3/30/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11.1.4(a) Elevators Placed in Inactive Status | Yes | Yes | This unit will be inactive status until the owner decides whether to remove or modify. They owner is currently not using this unit because it only goes to two of the three floors in the building |