Inspection
Inspection Details
Equipment ID
20406
20406
Inspection Date
5/4/2018
5/4/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Rick Buttice
Rick Buttice
Mechanic Name
Relief Valve Pressure
350
350
Slide
Governor Rope Pull
Door Closing Force
15
15
External ID
Location
Hotel Ignacio
3407 Olive St, St. Louis, MO
Phone: (314) 743-1352
3407 Olive St, St. Louis, MO
Phone: (314) 743-1352
Owner
Hotel Ignacio
3407 Olive St, St. Louis, MO 63103-1116
3407 Olive St, St. Louis, MO 63103-1116
Billing
Attn: HOTEL IGNACIO
3407 OLIVE ST, , MO 63103-1116
3407 OLIVE ST, , MO 63103-1116
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | n/a | Water and excessive corrosion in the pit shall be addressed. | 2/2/2021 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | There is excessive corrosion on the pit equipment. Remove corrosion and take corrective measures to eliminate corrosion. | 2/2/2021 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.11.2.1.2(e) (Re-Inspection) | Can not use machine room as storage. | 2/2/2021 | ||
A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | x | OSV needs to be tested with full load within 90 days. | 8/23/2022 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | Pit light does not work. Replace or repair item as needed. | 9/4/2024 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.5 Sump pump shall be provided | x | Pit had water in it because sump pump does not work causing major corrosion in the pit and on the pit channel. Needs to be addressed. | 8/23/2022 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | Clean the pit. | 9/4/2024 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | Provide means to prevent ground water from entering the pit. | 9/4/2024 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | Provide means to prevent rust on the existing pit equipment. | 9/4/2024 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | Provide current year tested fire extinguisher in the elevator machine room. | 9/4/2024 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.7.2.1 | Remove all non elevator related items from the elevator machine room. | 9/4/2024 | ||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current State Elevator Certificate. | 9/4/2024 |