Inspection
Inspection Details
Equipment ID
6919
6919
Inspection Date
6/19/2018
6/19/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
14
14
External ID
Location
St. Louis Marriott West
660 Maryville Centre Dr, Town & County, MO
Phone: (314) 878-2747
660 Maryville Centre Dr, Town & County, MO
Phone: (314) 878-2747
Owner
PMO III, LLC
660 Maryville Centre Dr, Town & Country, MO 63141
660 Maryville Centre Dr, Town & Country, MO 63141
Billing
Attn: St. Louis Marriott West
660 Maryville Centre Dr, , MO 63141
660 Maryville Centre Dr, , MO 63141
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | No monthly fire log. | 1/28/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current operating certificate. | 1/28/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Repair door knob in machine room. | 10/19/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display updated operating certificate in machine room. | 10/19/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Drain standing water from pit. | 1/4/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working. Re-inspection required | 2/26/2024 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Hoist ropes are showing signs of wear and stretching, need to replace the ropes within 60 days. Re-inspection required | 2/26/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 3/11/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current operating certificate shall be displayed in the machine room | 3/11/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 2/12/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The following tests need to be performed to complete 5 year inspection: full load, full speed car safeties, full load, full speed car buffer, counterweight safeties, 125% brake, overspeed governor jaw and switch speeds, overspeed governor pull thru, safeties pull out. Re-inspection required | 2/26/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Elevator lost traction before actuating top final limit switch. Red-tagged, Re-inspection required | 2/12/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Safety actuating arm appears to strike pit equipment when running down onto bottom final limit switch, repair same. Re-inspection required | 2/12/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The following tests need to be performed to complete 5 year inspection: full load, full speed car safeties, full load, full speed car buffer, counterweight safeties, 125% brake, overspeed governor jaw and switch speeds, overspeed governor pull thru, safeties pull out. Re-inspection required | 3/27/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 2/12/2026 |