Inspection
Inspection Details
Equipment ID
7633
7633
Inspection Date
11/1/2019
11/1/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Scott Fischer
Scott Fischer
Relief Valve Pressure
375
375
Slide
Governor Rope Pull
Door Closing Force
14
14
External ID
779e071d-1fa1-49fd-8f04-e490cbec7edd
779e071d-1fa1-49fd-8f04-e490cbec7edd
Location
Hampton Inn & Suites
55 DUNN RD, FLORISSANT, MO
Phone: (314) 839-2200
55 DUNN RD, FLORISSANT, MO
Phone: (314) 839-2200
Owner
Attn: UNK
Kinseth Hospitality
2 QUAIL CREEK CIR, NORTH LIBERTY, IA 52317
Phone: (000) 000-0000
Kinseth Hospitality
2 QUAIL CREEK CIR, NORTH LIBERTY, IA 52317
Phone: (000) 000-0000
Billing
Attn: Sreemanth Gollamudi
Quality Inn
55 DUNN RD, FLORISSANT, MO 63031
Phone: (314) 983-8895
Email: sreemanth.g@gmail.com
Quality Inn
55 DUNN RD, FLORISSANT, MO 63031
Phone: (314) 983-8895
Email: sreemanth.g@gmail.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Replace the leaking victaulic seal where needed. | 11/1/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display the current state operating certificate. | 11/14/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 10/25/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | The in car emergency telephone shall be operational. | 4/13/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 10/25/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. | 10/25/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be obtained and displayed in the elevator machine room. | 10/25/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.5 Code Data Plate | No | No | Install a code data plate, it shall read "Missouri Minimum". | 6/26/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | The disconnect located in the machine space shall be provided with a sign to identify the location of the supply side overcurrent protective device. | 6/26/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The in-car emergency telephone shall be operational. | 6/22/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | OSV shall have current testing tag. Existing OSV trips at 101 fpm (car contract speed is 150 fpm). Repair or replace as needed for proper operation. A successful category 5 test shall be witnessed once repairs are made. | 10/17/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The entire annual inspection still needs to be completed. Issue with the OSV prevented the annual inspection. | 10/17/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a non-combustible frame with a clear protective vision plate over it. | 6/3/2025 |