Inspection
Inspection Details
Equipment ID
7850
7850
Inspection Date
4/19/2018
4/19/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
Relief Valve Pressure
370
370
Slide
Governor Rope Pull
Door Closing Force
External ID
Location
Sigma Chemical-Dekalb Bldg
3500 Dekalb, St. Louis, MO
Phone: (314) 771-5765
3500 Dekalb, St. Louis, MO
Phone: (314) 771-5765
Owner
Sigma Chemical
PO Box 14508, St Louis, MO 63178
PO Box 14508, St Louis, MO 63178
Billing
Attn: Sigma Chemical
3300 S Second St, , MO 63118
3300 S Second St, , MO 63118
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light and bell are inoperative. Repair. | 8/27/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A copy of the MCP shall be kept in the machine room for each elevator | 5/22/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | No | No | Fire fighters Phase I instruction sign at key switch is not legible. Replace sign | 5/22/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | Hoistway doors at middle landing shall be adjusted to reduce gap between doors when closed and locked | 5/22/2023 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)1 | No | No | Remove mounted fire extinguisher from inside the elevator. See ‘96 204.3a | 5/19/2023 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)6 | No | No | Post missing signs in car as needed. No pass., class freight. | 5/19/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace missing cotter pin on car door rod(s) as needed. | 5/19/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean the pit. | 5/19/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace missing controller cooling fan. | 5/19/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Provide existing emergency lights and bell to work. | 5/12/2023 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)6 | No | No | Provide Loading class" sign in car enclosure. | 9/24/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit needs to be cleaned | 9/24/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Gate to machine space needs to be self locking | 9/24/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Pipes over elevator controllers and disconnect switches need to be guttered to prevent and possible leakage from getting into electrical equipment | 9/24/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm in car is not working. Re-inspection required | 4/25/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light in car is not working on backup power. Re-inspection required | 4/25/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Bottom hoistway access pull chain box is broken, repair or replace same | 5/13/2025 |