Inspection
Inspection Details
Equipment ID
19955
19955
Inspection Date
11/18/2019
11/18/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Rick Brenner
Rick Brenner
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
d55e2ba0-d1e8-430d-aa46-171a88cfd8de
d55e2ba0-d1e8-430d-aa46-171a88cfd8de
Location
Vintage Stock
2040 CHESTERFIELD MALL, CHESTERFIELD, MO
Phone: (636) 489-1062
2040 CHESTERFIELD MALL, CHESTERFIELD, MO
Phone: (636) 489-1062
Owner
Attn: Vintage Stock
Vintage Stock
202 E 32ND ST, JOPLIN, MO 64804
Phone: (000) 000-0000
Email: seth.bayless@vintagestock.com
Vintage Stock
202 E 32ND ST, JOPLIN, MO 64804
Phone: (000) 000-0000
Email: seth.bayless@vintagestock.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Handrail torn on left side needs replacing | |
| conversion | conversion | n/a | No | No | Top E-stop switch, no buzzer on cover Bottom also | |
| conversion | conversion | n/a | No | No | Handrail inlet cover piece missing | |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Upper & Lower demarcation lights not working | |
| A17.1-1996 : Elevators | 5.7 - Car frame and platform | 203.6 | No | No | Electrical greenfield in bottom of controller torn open needs repair | |
| A17.1-1996 : Escalators | 7.5 - Lighting | 805.7 | No | No | Upper demarcation lights not working | |
| A17.1-1996 : Escalators | 8.3 - Controller and wiring | 806 | No | No | Electric greenfield in bottom controller, torn open, needs repair | |
| A17.1-1996 : Escalators | 7.5 - Lighting | 806.2 | No | No | Reinspection of demarcation lightening-failed and torn elect conduit on pit failed. No violations have been corrected. Reinspection needed | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.5.2(i) Demarcation lighting | Yes | No | Upper and lower demarcation lights not working | 3/2/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Need maintenance control program on site | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2 | No | No | Emergency stop switch cover broken off at bottom | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2 | No | No | Wiring going into bottom of controller, greenfield coming apart, needs to be repaired | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.4 Escalator Combplates | Yes | No | complete annual test Bottom comb impact vertical test | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.4 Escalator Combplates | No | No | Replace section comb plate missing teeth | |
| A17.1-1996 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 806 | No | No | Replace greenfield feeding the controller open & pulled loosed | |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room |