Inspection
Inspection Details
Equipment ID
4402
4402
Inspection Date
11/8/2019
11/8/2019
Inspection Type
Major Alteration
Major Alteration
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
Edward Bauer
Edward Bauer
Relief Valve Pressure
645
645
Slide
Governor Rope Pull
Door Closing Force
20
20
External ID
15584dc8-0b20-47da-80bc-66e607df7c42
15584dc8-0b20-47da-80bc-66e607df7c42
Location
Piper Medical Bldg
112 PIPER HILL DR, SAINT PETERS, MO
Phone: (636) 399-5364
112 PIPER HILL DR, SAINT PETERS, MO
Phone: (636) 399-5364
Owner
Piper, Terrance
112 PIPER HILL DR, SAINT PETERS, MO 63376-1690
112 PIPER HILL DR, SAINT PETERS, MO 63376-1690
Billing
Attn: St. Peters Office Associates
4800 MEXICO RD STE 105, SAINT PETERS, MO 63376-1666
4800 MEXICO RD STE 105, SAINT PETERS, MO 63376-1666
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | An ABC fire extinguisher with a current test tag shall be provided convenient to the machine room access door. | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.11.2.1.2(e) (Re-Inspection) | No | No | The machine room shall not be used for storage of non-elevator related materials. | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Instructions for locating maintenance records shall be posted as required by A17.1 2016 - 8.6.1.4.2 | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A checkout procedure for the 2 way communication system shall be provided by A17.1 2016 - 8.6.1.2.2(c)(3) | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A checkout procedure for the over-speed valve shall be provided by A17.1 2016 - 8.6.1.2.2(c)(5) | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | An evacuation procedure shall be made available as required by A17.1 2016 - 8.6.1.2.2(d)(1) | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A call-back log shall be provided as required by A17.1 2016 - 8.6.1.4.2 | 4/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) | 12/3/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.7.2.1 | No | No | Machine room shall be for elevator equipment only. | 4/17/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency lighting shall work. | 12/12/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Non-elevator related items shall not be stored in the machine room. (file cabinet, office chair, ect) | 12/12/2025 |