Inspection
Inspection Details
Equipment ID
427
427
Inspection Date
11/12/2019
11/12/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James Mueller
James Mueller
Mechanic Name
Bill Suedkamp
Bill Suedkamp
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
26
26
External ID
e62b5a46-34ed-4704-9930-8f1462667a77
e62b5a46-34ed-4704-9930-8f1462667a77
Location
Maritz Inc
1375 N HIGHWAY DR, FENTON, MO
Phone: (636) 827-3176
1375 N HIGHWAY DR, FENTON, MO
Phone: (636) 827-3176
Owner
Attn: Maritz Inc
Maritz Inc
1375 N HIGHWAY DR, FENTON, MO 63026
Phone: (000) 000-0000
Email: russ.mangnall@maritz.com
Maritz Inc
1375 N HIGHWAY DR, FENTON, MO 63026
Phone: (000) 000-0000
Email: russ.mangnall@maritz.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | x | Suspension (Hoist Ropes) are rouged badly, and do not meet manufacturers minimum diameter requirements. The hoist ropes shall be replaced. | 3/28/2019 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | x | The car door restrictor shall be operational. | 10/25/2021 | |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)1(A) | Hoist rope and governor rope data tags are missing. | 8/8/2023 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The machine room door shall have a self-locking door and shall be operable from the interior space without the use of a key. | 8/8/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) | 8/8/2023 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO state operating certificate shall be displayed in the elevator machine room. | 8/8/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | The disconnect located in the machine space shall be provided with a sign to identify the location of the supply side overcurrent protective device. | 8/8/2023 | ||
| MO Minimum : Elevators | (I) - Pits | (I)3 | Counterweight guards shall extend from a point not more than twelve inches (12") above the pit floor to a point not less than seven feet (7') above the pit floor. | 8/8/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | Install a code data plate. It shall read: Missouri Minimums | 8/8/2023 | ||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)11 | Wedge rope socket is anchored incorrectly. When the steel wire rope has been seated in the wedge socket by the load on the rope, the wedge shall be visible, and at least two wire-rope retaining clips shall be provided to attach the termination side to the load-carrying side of the rope. The first clip shall be placed a maximum of 4 times the rope diameter above the socket, and the second clip shall be located within 8 times the rope diameter above the first clip. | 8/8/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | x | The door restrictor shall be operational. | 10/4/2022 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) | Need procedures for inspections and test not described in A17.2. (This item is for notification purposes for future violation in 2022) | 8/8/2023 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Elevators that are equipped to operate on emergency power shall be tested with no load in the car while operating on the emergency generator. | 10/4/2022 |