Inspection
Inspection Details
Equipment ID
10539
10539
Inspection Date
4/19/2018
4/19/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
30 Lbj
30 Lbj
External ID
Location
James House
4310 St. Ferdinand, St. Louis, MO
Phone: (314) 652-8997
4310 St. Ferdinand, St. Louis, MO
Phone: (314) 652-8997
Owner
St Louis Housing Authority
3520 Page Blvd, St Louis, MO 63106
3520 Page Blvd, St Louis, MO 63106
Billing
Attn: St Louis Housing Authority
3520 Page Blvd, , MO 63106
3520 Page Blvd, , MO 63106
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | n/a | Clean pit | 10/21/2019 | ||
conversion | conversion | conversion - reinspect | x | Emergency bell inoperative repair | 5/24/2019 | |
conversion | conversion | n/a | Cover 9th floor hoistway door lock | 10/21/2019 | ||
conversion | conversion | n/a | Restricted opening disabled, repair | 10/21/2019 | ||
conversion | conversion | n/a | Reduce door closing force pressure | 10/21/2019 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Phone in elevator cab does not work. | 7/16/2021 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Reprogram emergency phone to call | 9/23/2021 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Phone in elevator cab does not work, needs repair. Re-inspection required | 10/5/2022 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | x | Car door restrictor does not work, needs repair. Re-inspection required | 10/5/2022 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Phone in elevator cab does not work. Phone line problem | 4/9/2024 | |
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Elevator cab alarm bell does not work, needs repaired. Re-inspection required | 6/27/2024 | |
A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.6.4.13.1(l)(Door Restrictor) | x | Elevator car door restrictor does not work. Re-inspection required | 6/27/2024 | |
A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | x | Need to clean debris from pit. Re-inspection required | 6/27/2024 |