Inspection
Inspection Details
Equipment ID
11701
11701
Inspection Date
5/17/2018
5/17/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Relief Valve Pressure
350
350
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
16
16
External ID
11701
11701
Location
Maplewood Loop Apts
2286 Yale Ave, Maplewood, MO
Phone: (314) 469-2222
2286 Yale Ave, Maplewood, MO
Phone: (314) 469-2222
Owner
Maplewood Apt
225 S, Meramec, Ste. 301, St. Louis, MO 63105
225 S, Meramec, Ste. 301, St. Louis, MO 63105
Billing
Attn: Maplewood Apt
1035 L Oak Forest Parkway, , MO 63146
1035 L Oak Forest Parkway, , MO 63146
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Repair car floor at entrance--tripping hazard | 7/23/2018 |
| conversion | conversion | n/a | No | No | Repair emergency light & bell | 7/23/2018 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform month fire service test & document on log in machine room | 5/28/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor | 5/28/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Replace jack packing | 5/28/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency phone not working | 8/31/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 7/19/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 7/19/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor | 7/19/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Replace jack packing | 7/19/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service and document on log in machine room | 3/16/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 5/4/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Repair lights in car and reinstall missing section of false ceiling or install guards on bulbs | 7/24/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Provide adequate lighting in the machine room | 5/4/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean the pit | 5/4/2024 |