Inspection
Inspection Details
Equipment ID
19899
19899
Inspection Date
1/8/2020
1/8/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Paul Bartlett
Paul Bartlett
Relief Valve Pressure
265
265
Slide
Governor Rope Pull
Door Closing Force
20
20
External ID
33bffaab-8934-4e0f-b03c-4d877cd7fe40
33bffaab-8934-4e0f-b03c-4d877cd7fe40
Location
Valley Center Bldg #4
215 W MILL ST, SPRINGFIELD, MO
Phone: (417) 889-0951
215 W MILL ST, SPRINGFIELD, MO
Phone: (417) 889-0951
Owner
Brick City
PO BOX 9123, SPRINGFIELD, MO 65801-9123
PO BOX 9123, SPRINGFIELD, MO 65801-9123
Billing
Attn: Brick City
440 N CAMPBELL AVE, SPRINGFIELD, MO 65806-1259
440 N CAMPBELL AVE, SPRINGFIELD, MO 65806-1259
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | 1.18.1: Car Door restrictor shall work. (REINSPECTION WITHIN 30 DAYS) | 1/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.3 Guards Between Adjacent Pits | No | No | Pit shall be kept dry. Remove rust from pit channels, repaint, repair water leak. | 1/25/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | 1.18.1: Car Door restrictor shall work. (REINSPECTION WITHIN 30 DAYS) | 1/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.3 Guards Between Adjacent Pits | No | No | Pit shall be kept dry. Remove rust from pit channels, repaint, repair water leak. | 1/22/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | G/2.7.1/8.6.1.6.5: Machine Room Fire Extinguisher shall have current monthly/annual test tag. No tag | 9/23/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Permanently mount telephone line/flex to wall per NEC code | 9/23/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | ALARM BELL SHALL WORK WITH LOSS OF MAIN 120v POWER (REINSPECTION => 30days) (broken button) | 10/31/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine Room Fire Extinguisher shall have current monthly/annual test tag, no date present. (4lb ABC, replace with appropriate) | 11/22/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Lamps(overhead Cab lighting) shall be guarded. Missing ceiling panels. | 11/22/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Repair sump pump, spraying pit equipment, clean pit, remove rust from piping/jack. Repaint to reduce future rusting. Monitor for leaks. | 11/22/2022 |