Inspection
Inspection Details
Equipment ID
9182
9182
Inspection Date
5/3/2018
5/3/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
NA
NA
External ID
9182
9182
Location
Macy's- West Store / #652
#2 West County Center , Legal Number 120012, St. Louis, MO
Phone: (314) 966-0017
#2 West County Center , Legal Number 120012, St. Louis, MO
Phone: (314) 966-0017
Owner
Macy's
7 West 7th St, 19th Floor, Cincinnati, OH 45202
7 West 7th St, 19th Floor, Cincinnati, OH 45202
Billing
Attn: Macy's
7 West 7th St. 19th Floor, , OH 45202
7 West 7th St. 19th Floor, , OH 45202
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | Left handrail bad and must be replaced, replace step rollers | 11/18/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Clean down truss | 11/18/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Provide a complete maintenance control program to include wiring diagrams | 11/18/2025 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room | 11/18/2025 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room | 11/18/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Clean down trusses | 11/18/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | Replace right handrail | 11/18/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.11.4.1(e) Lighting (demarcation and step lighting) | No | No | Repair upper and lower skirt entrance lighting | 11/18/2025 |
| A17.1-1996 : Escalators | 8.12 - Steps, step chains, and trusses | 801.1 | No | No | Clean Down Truss | |
| A17.1-1996 : Escalators | 7.5 - Lighting | 806.2 | No | No | Repair Skirt Entrance Lights | |
| A17.1-1996 : Escalators | 7.3 - Handrails | 1008.2m Handrails | No | No | Replace Right Handrail |