Inspection
Inspection Details
Equipment ID
23537
23537
Inspection Date
12/19/2019
12/19/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Don McFadden, Jr.
Don McFadden, Jr.
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
22
22
External ID
c458c8c5-b7e6-4ba3-a94e-64fb73a0536b
c458c8c5-b7e6-4ba3-a94e-64fb73a0536b
Location
The Buell Building
1900 WASHINGTON AVE, SAINT LOUIS, MO
1900 WASHINGTON AVE, SAINT LOUIS, MO
Owner
Attn: Jewel of the Plaza LLC
Jewel of the Plaza LLC
393 N EUCLID AVE, SAINT LOUIS, MO 63108
Phone: (000) 000-0000
Jewel of the Plaza LLC
393 N EUCLID AVE, SAINT LOUIS, MO 63108
Phone: (000) 000-0000
Billing
Attn: Red Brick Management
Red Brick Management
393 N EUCLID AVE, SAINT LOUIS, MO 63108
Phone: (000) 000-0000
Email: steve@redbrickstl.com
Red Brick Management
393 N EUCLID AVE, SAINT LOUIS, MO 63108
Phone: (000) 000-0000
Email: steve@redbrickstl.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.11.2.1.2(g) | No | No | Provide a current tested fire extinguisher in the elevator machine room. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4 | No | No | Provide feeder location on main line and 110v disconnect. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display a copy of the current state operating certificate. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.15 - sign and operating device symbols | 8.11.2.1.1(o) | No | No | Post elevator lobby warning placards on all floors. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.9 - Floor and emergency identification numbering | 8.11.2.1.3(o) | No | No | Provide elevator numbering inside hoistway at all doors. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide a completed maintenance control program (MCP) on site. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be displayed in the elevator machine room. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide a code compliant MCP including onsite documents. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.9 - Floor and emergency identification numbering | 8.11.2.1.3(o) | No | No | Provide floor numbering on inside of hoistway doors. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.9 Elevator Corridor Call Station Pictograph | No | No | Provide "In case of fire" signage on all floors. | 12/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.4 - Normal terminal stopping devices | 8.11.2.2.5 | Yes | No | The bottom limit switch shall be adjusted to stop the movement of the car prior to striking the buffer. | 3/2/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.5 - Normal terminal stopping device | 8.11.2.1.3(g) | Yes | No | The upper terminal device shall be adjusted to stop the movement of the car prior to contacting the directional limit switch. | 3/2/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.9 - Floor and emergency identification numbering | 8.11.2.1.3(o) | No | No | Hoistways shall have floor numbers, not less than 4 inches in height, on the hoistway side of the hoistway door. | 10/22/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.17 - Door and gate equipment | 8.11.2.1.3(w) | No | No | Stops shall be provided to prevent hoistway door hangers from overrunning the track. | 10/22/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.9 - Power closing of doors or gates | 8.11.2.1.1(i) | No | No | The door data plate shall be completed with the door speeds. | 10/22/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.4 - Sills and car floor | 8.11.2.1.1(d) | No | No | There is missing carpet inside the car that creates an unlevel and unsafe surface. | 10/22/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.12 - Car enclosure | 8.11.2.1.1(l) | No | No | The position indicator shall be securely attached to the car enclosure. | 10/22/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The emergency two-way communication does not work when car 110v removed. | 3/2/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The emergency recording gives the wrong location. | 3/2/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.4 - Normal terminal stopping devices | 8.11.2.2.5 | Yes | No | The bottom limit switch shall be adjusted to stop the movement of the car prior to striking the buffer. | 4/25/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.5 - Normal terminal stopping device | 8.11.2.1.3(g) | Yes | No | The upper terminal device shall be adjusted to stop the movement of the car prior to contacting the directional limit switch. | 4/25/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the machine room, in a noncombustible frame with a clear protective vision plate over it. | 10/22/2025 |