Inspection
Inspection Details
Equipment ID
5639
5639
Inspection Date
6/6/2018
6/6/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
John Ryan
John Ryan
Mechanic Name
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
External ID
Location
Monsanto Bldg GG
700 Chesterfield Pkwy N, Chesterfield, MO
Phone: (636) 247-6780
700 Chesterfield Pkwy N, Chesterfield, MO
Phone: (636) 247-6780
Owner
CBRE % Monsanto
700 Chesterfield Pkwy West, Chesterfield, MO 63017
700 Chesterfield Pkwy West, Chesterfield, MO 63017
Billing
Attn: Monsanto
700 Chesterfield Parkway North, , MO 63017
700 Chesterfield Parkway North, , MO 63017
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an overspeed valve that in not sealed. A category 5 test shall be performed on the overspeed valve on or before the next annual inspection. The valve shall be sealed and tagged after the category 5 test. | 3/12/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Emergency/standby power shall be tested. Note: The unit has an indicator light and key-switch for emergency power. Building personnel were unsure if this unit is served by a generator in the case of a grid failure. If it is, it shall be tested. If it isn't, the related fixture shall be removed. | 3/15/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 3/12/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | When the hall fire recall key-switch is in the "ON" position, or an initiation device has been activated, a stopped car shall have the in-car stop switch rendered inoperative as soon as the car moves away from the landing. A moving car shall have the switch rendered inoperative without delay. Note: The acceptance tests were witnessed by St. Louis County last month. The code data plate is marked for compliance with A17.1-2013, as required by St. Louis County. A17.1-2013 requires the switch to be rendered inoperative. A17.1-2016 (the current MO State code) does not. | 3/15/2023 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.1.6(c) Stop Switch Inoperable in Fire Service (Re-Inspection) | Yes | No | When the hall fire recall key-switch is in the "ON" position, or an initiation device has been activated, a stopped car shall have the in-car stop switch rendered inoperative as soon as the car moves away from the landing. A moving car shall have the switch rendered inoperative without delay. Note: The acceptance tests were witnessed by St. Louis County last month. The code data plate is marked for compliance with A17.1-2013, as required by St. Louis County. A17.1-2013 requires the switch to be rendered inoperative. A17.1-2016 (the current MO State code) does not. This violation was originally cited in 2022 and has not been addressed. Customer to apply for a variance from the State of Missouri to clear violation. | 5/28/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted near the equipment, in a noncombustible frame with a clear protective vision plate over it. | 3/12/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The emergency/standby power shall be tested. | 3/24/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Emergency power operation shall be tested. | 3/12/2026 |