Inspection
Inspection Details
Equipment ID
1452
1452
Inspection Date
5/3/2018
5/3/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
NA
NA
External ID
1452
1452
Location
Macy's- West Store / #652
#2 West County Center , Legal Number 120012, St. Louis, MO
Phone: (314) 966-0017
#2 West County Center , Legal Number 120012, St. Louis, MO
Phone: (314) 966-0017
Owner
Macy's
7 West 7th St, 19th Floor, Cincinnati, OH 45202
7 West 7th St, 19th Floor, Cincinnati, OH 45202
Billing
Attn: Macy's
7 West 7th St. 19th Floor, , OH 45202
7 West 7th St. 19th Floor, , OH 45202
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | REpair skirt lighting | 6/15/2020 |
| A17.1-1996 : Escalators | 7.5 - Lighting | 806.2 | No | No | Repair skirt light top of unit | 6/15/2020 |
| A17.1-1996 : Escalators | 7.15 - Balustrades | 802.3 | No | No | Replace missing Balustrate trim | 6/15/2020 |
| A17.1-1996 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 802.3e | No | No | Provide copy of missing step index test results to complete inspection | 6/15/2020 |
| A17.1-1996 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 806 | No | No | Clean down trust | 6/15/2020 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Need maintenance control program on site posted on controller | 10/3/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | right handrail torn needs replacing | 10/3/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Unit needs to be cleaned down | 10/3/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.11.4.2.13 Escalator Handrail Safety Systems | No | No | left handrail torn needs replacing | 10/3/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Clean down truss | 10/3/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Provide a complete maintenance control program to include wiring diagrams | 10/3/2025 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room | 10/3/2025 |